Alarms Signal; No Acc; No Fire; Cool Fire - livin flame Skomo User And Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Alarms signal

In the event of a working defect, the system informs
the user about the type of failure occurred. The
following table summarises the alarms, kind of
problem and possible solution:

No acc

This alarm occurs when the time foreseen for a light up
(around 15 minutes) passes and the smokes temperature
is still too low. This can occur also when there is not
enough pellets fl ow to light up the unit. Press the key On/
Off on the control board to reset the alarm. Wait until the
cooling phase is completed, clean the brazier and start up
with a new switching on.

No fire

This alarm occurs in the event the stove switches off
during its working phase (for example if there is no pellets
left in the pellets tank). You will read the words "Alarm No
fi re" on the display. Press the key On/Off on the control
board to reset the alarm. Wait until the cooling phase
is completed, clean the brazier and start up with a new
switching on.

Cool fire

In the event of an even very short lack of current, the
stove switches off. As soon as the power supply is back,
the stove will start a cooling cycle and the display will
show the words "Cool fi re". After completing the cooling
cycle, the stove will start up again.
NOTE: If your stove is supplied with a remote control
and there is a lack of current, remember to program the
eventual switching on and off times again. In the event
of a lack of current, the stove will loose any previous time
settings.
Once the power supply is back, press the key SEND
on the remote control to retransmit the automatic
programming you previously set to the stove.
Fan fail
This alarm occurs in the event the smokes ejector is broken
or the pcb cannot detect the speed of the smokes exhaust
fan. In this case press the key On/Off to reset the alarm
and contact the technical assistance.
Dep Sic fail
This alarm is signalised by the Leds ALF and ALC blinking
on the control board.
It indicates two different possibilities: an obstruction in
the fl ue or a possible overheating of the stove. In both
cases the motor reducer to load the endless screw stops
working and the stove switches off. Press the key On/Off
to reset the alarm. Check the possible activation of the
manual reset thermostat on the back of the stove (4).
Unscrew the safety cap and press the key.
In the event you have the same problem more than once,
please contact the technical assistance.
Regular checks should be carried out by the user, who should only contact the Authorized
Assistance Center if no solution is found.
Sond fumi
This alarm occurs in the event the sensor for smokes
temperature is broken or not connected. You will read the
words Alarm Son fumi on the display. In this case press the
key On/Off to reset the alarm and contact the technical
assistance.
Serv
The signal "Serv" on the display means that the stove
has reached 1200 hours working. Please contact an
authorised technical service to arrange a supplementary
maintenance.
1
2
3
1. Lighting button
2. Fuse F4AL250V
3. Thermostat reset button
4. Environmental probe
Replace the batteries of the remote control
If you need to replace the batteries of the remote control,
remove the back cover as shown in the picture. Replace the
old batteries with the new ones respecting the polarity + and
-. The batteries needed are AAA, 1,5 V.