Regulations

3
Regulations
All local by-laws and regulations pertaining to installation and
use of gas appliances must be observed.
This appliance must be installed in accordance with the
manufacturers installation instructions, AS/NZS5601, AS/
NZS3500 and all Local Building & Gas fitting regulations.
This appliance must not be installed indoors or in an enclosed
space. This appliance is approved for outdoor installation only.
Failure to install this appliance in accordance with these
installation instructions will void the warranty and may create
an unsafe situation.
4

Installation

DANGER:
This appliance must not be installed indoors
or in an enclosed space in accordance with
AS/NZS5601.
DANGER: Explosion Risk!
▶ Always turn off the gas valve before
carrying out any work on components
which carry gas.
DANGER: Appliance malfunction!
This appliance must be installed with no
obstructions to air entry openings at the
front, rear, side, or top.
▶ Periodic checking of openings to ensure
no blockage or obstruction of the air
openings from plants, debris, or insects
must be carried out.
DANGER: Property damage!
If this appliance is to be installed on a
combustible surface:
▶ Use a heat shield as per AS/NZS5601.
8
=
Fig. 3
Minimum heat shield requirements
The installation and the initial startup are to
be carried out only by an authorised person.
Not suitable for pool, spa pool, or solar
booster application.
Not suitable for commercial boosting of a
warm water recirculation system.
This appliance should only be installed in
applications where incoming cold water
temperature does not exceed 40 °C.
Minimum water supply pressure must meet
the requirements set out in table 5.
Water fixtures and appliance settings must
ensure that the flow rate of hot water does
not fall below the minimum requirement.
To reduce the chance of corrosion,
installation in a marine environment should
be avoided. Premature corrosion due to the
installation environment would not be
covered by warranty.
Pilot Ignition – 6 720 886 398 (2021/02)