Diagnostic Page

In the diagnostics page, you can find important system operating information.
System power on time (hours)
System power on time records total the accumulated number of operating hours.
LED power on time (hours)
LED power on time as the total LED ON hours.
Inputs
The Input state reports the input voltage of power supply to CaMate. It records the Max. and Min.
voltage ever recorded, the average voltage during operation, and the current voltage reading. The
Out of range count records the event when the input voltage is under DC12V ‐10% (DC10.8V) or over
the AC24V+10% (AC26.4V).
LED Voltage
The LED voltage reports the health condition for LED strings, as there are 4 LED strings in CaMate.
The normal LED ON voltage should fall between 400mV and 1200mV. The Over range count records
the event when the detected LED voltage is over 1200mV. Once the LED voltage is over range, the
LED is probably damaged. The 4 LED strings work independently.