NPL-4/5/RM-104
Troubleshooting Instructions
Now the measurement setup, which has been built according to the Check synthesizer
Operation-chapter, should detect the following output signal of the phone.
P
= +23dBm @ 836.6 MHz
out
If this is not the case, then go to the chapter GMSK for the troubleshooting.
Start the preparations as described in chapter Check synthesizer Operation.

EDGE

Select operation mode to the "local".
Select->Testing -> RF control
In the popup window common values:
Active unit:->TX
Band: ->850
Operation mode: ->Burst
RX/TX Channel:->190
In the popup window TX control values:
EDGE:->ON
Copyright © 2005 Nokia Corporation. All rights reserved.
Page 30
Company confidential
Figure 20: RF Controls