Nokia NPL-4 Series Troubleshooting Instructions page 95

Transceivers
Hide thumbs Also See for NPL-4 Series:
Table of Contents

Advertisement

Company confidential
NPL-4/5/
Nokia Customer Care
Troubleshooting Instructions
Check difference of offset strap coil
- difference of measured values must be range of 320 to 420digit for both channels
Check Set/Reset pulses and VBridge voltage
- measure with oscilloscope
- S/R pulses and Vbridge voltages are active only during the measurement phase
Check measurement bridges output voltages
- Voltages referred to ground must be near 1.1V and difference signal 0.0V
Copyright © 2005 Nokia Corporation. All rights reserved.
Issue 2 05/05
Page 95

Advertisement

Table of Contents
loading