Additional Information For Edge Troubleshooting; Edge Mode Troubleshooting Differs Slightly From Basic Gsm Troubleshooting - Nokia NPL-3 Series Troubleshooting Instructions

Transceivers
Hide thumbs Also See for NPL-3 Series:
Table of Contents

Advertisement

CCS Technical Documentation

Additional information for EDGE troubleshooting

EDGE mode troubleshooting differs slightly from basic GSM troubleshooting.

Establish connection to the phone normally (see GSM850/1800/1900 troubleshooting
instructions).
Select product from the menu:
File -> Choose Product -> NPL-3
From toolbar set operating mode to "Local"
Activate RF controls window from the menu:
Testing -> RF Controls
From the RF controls window:
Select Band "GSM850" or "GSM1800" or "GSM1900" (Default="GSM850")
Set Active unit to "Tx" (Default="Rx")
Set Edge "On" (Default="Off")
Set Operation mode to "Burst" (Default="Burst")
Set Tx data type to "Alternate PN9" (Default="All1")
Set Rx/Tx channel to 190 on GSM850 or 700 on GSM1800 or 661 on GSM1900
(Defaults)
Set power level to 8 (Default = 19) on GSM850 or to 2 (Default = 0) on GSM1800 or
GSM1900
NOTE! For GSM850 Edge power levels 5, 6 and 7 are not in use and for GSM1800&1900 Edge power
levels 0 and 1 are not in use.