97243C Single Valve Control Assembly INSTALLER 4410FR Fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES.
4410FR_FTN LK4410FR_FTN INSTALLATION INSTRUCTIONS IMPORTANT THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
Page 3
4410FR_FTN LK4410FR_FTN SITE PREPARATION DETAIL FOR THE 4410FR FTN. WHEN USING 97243C SINGLE VALVE CONTROL ASSY. PVC COLUMN CENTERED BETWEEN MOUNTING BOLT HOLES (6) 1/2" (13mm) DIA. HOLES EQUALLY SPACED ON A 12" (305mm) BOLT CENTER O 14" FIG. 1...
4410FR_FTN LK4410FR_FTN TROUBLE SHOOTING AND MAINTENANCE Insufficient Bubbler Flow: Check that the shut-off valve is wide open. Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body. Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve. No Flow: Check for leaks in the air tubing going from the push button to the valve. Make sure the air tubing compression nut is hand tight. Disconnect air tube from push button. Place finger over air outlet. Push button to test diaphragm. Tighten diaphragm cap screws. Replace diaphragm if necessary.
Page 5
4410FR_FTN LK4410FR_FTN 32, 32a, 32b Single Valve Assy. (Item 28) The following items are included with the 4410FR Fountain PARTS LIST ITEM NO. PART NO. DESCRIPTION 2, 10 100147140560 Drain Gasket 75589C Gasket 101449542550 Clamp - Hose 101570540560 Drain Gasket...
4410FR_FTN LK4410FR_FTN Owners Manual 4410 Freeze Resistant Tubular Fountain with SanitaryFR1 Valve IMPORTANT! INSTALLER PLEASE NOTE Tubing must be cut to the right length. Do not coil any excess tubing or it will cause valve to malfunction. General Installation Tips 1.
Page 7
4410FR_FTN LK4410FR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4410FR FTN. WHEN USING THE SANITARYFR1 VALVE 4" PVC 1/4 BEND (SUPPLIED BY INSTALLER) 1-1/2" DRAIN TUBE (SUPPLIED BY INSTALLER) 4" PVC PIPE (SUPPLIED BY INSTALLER) CONCRETE SLAB CLEANOUT PLUG FOR ACCESS 4"...
Page 8
4410FR_FTN LK4410FR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4410FR FTN. WHEN USING THE SANITARYFR1 VALVE 1-1/4 DRAIN TUBE SUPPLIED WITH FTN. ( 6 ) 1/2" ( 13mm ) DIA. HOLES EQUALLY SPACED ON A 12" ( 305mm ) BOLT CENTER AIR GAP ASSY.
Page 9
4410FR_FTN LK4410FR_FTN FOUNTAIN CONNECTIONS PLUMBING CONDUIT (BY INSTALLER) TO VALVE FIG. 3 INSTRUCTIONS FOR CONNECTING TUBES FROM VALVE TO FOUNTAIN Step 1 - Insert the 1/8” O.D. tube (Label A) into the connector (provided with fountain). Insert the 1/8” O.D. tube coming from the fountain push button actuator into the connector.
Page 10
4410FR_FTN LK4410FR_FTN Stream Height Adjustment 3, 11 See Detail B FIG. 5 FIG. 4 Detail B 97733C (Rev. N - 01/17) PAGE 10...
4410FR_FTN LK4410FR_FTN The Following Items are included with the SanitaryFR1 Valve PARTS LIST DESCRIPTION ITEM NO. PART NO. 110175443890 Hex Nut - 3/8-16 45806C Single Valve 50986C Regulator Holder 56082C Regulator Nut 56092C Poly Tubing - 1/4” (Cut To Length) - To Bubbler 56123C Poly Tubing - 1/8”...
Page 12
4410FR_FTN LK4410FR_FTN TROUBLE SHOOTING AND MAINTENANCE Trouble Shooting Insufficient Bubbler Flow: Check that the shut-off valve is wide open. Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body. Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve. No Flow: Check for leaks in the air tubing going from the push button to the valve. Make sure the air tubing compression nut is hand tight. Disconnect air tube from push button. Place finger over air outlet. Push button to test diaphragm. Tighten diaphragm cap screws. Replace diaphragm if necessary.