Electrolux EHT60330 User Manual page 12

Table of Contents

Advertisement

12 electrolux
A
A) The by-pass screw
• If you change from natural gas G20/G25
20/25 mbar to liquid gas, fully tighten the
by-pass screw in.
• If you change from liquid gas to natural
gas G20/G25 20/25 mbar, undo the by-
pass screw approximately 1/4 of a turn.
• If you change from natural gas G20/G25
20/25 mbar to town gas G130 8 mbar,
unscrew approximately 3/4 of a turn.
• If you change from town gas G130 8
mbar to natural gas G20/G25 20/25
mbar screw approximately 3/4 of a turn.
• If you change from liquid gas to town gas
G130 8 mbar unscrew approximately 1
turn.
Warning! Make sure the flame does
not go out when you quickly turn the
knob from the maximum position to the
minimum position.
ELECTRICAL CONNECTION
• Ground the appliance according to safety
precautions.
• Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the lo-
cal power supply.
• This appliance is supplied with a mains
cable. It has to be supplied with a correct
plug, able to support the load marked on
the rating plate. The plug has to be fitted
in a correct socket.
• Any electrical component must be instal-
led or replaced by the Service Force
Centre technician or qualified service per-
sonnel.
• Always use a correctly installed shock-
proof socket.
• Make sure that there is an access to the
mains plug after installation.
• Do not pull the mains cable to disconnect
the appliance. Always pull the mains
plug.
• The appliance must not be connected
with an extension cable, an adapter or a
multiple connection (risk of fire). Check
that the ground connection is in conform-
ity with the standard and regulations
force.
• The power cable must be placed in such
a way that it does not touch any hot part.
• Connect the appliance to the mains with
a device that lets to disconnect the appli-
ance from the mains at all poles with a
contact opening width of minimum 3
mm, eg. automatic line protecting cut-
out, earth leakage trips or fuse.
• None of a parts of the connection cable
can not get a temperature 90 °C. The
blue neutral cable must be connected to
the terminal block label with "N". The
brown (or black) phase cable (fitted in the
terminal block contact marked with "L")
must always be connected to the live
phase.
REPLACEMENT OF THE CONNECTION
CABLE
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown (or
black) phase wire.
BUILDING IN
min.
450 mm
min.
55 mm
30 mm
470 mm
min.
650 mm
550 mm