Appendix B: Additional wiring considerations
ASM LED status index
The ASM has two status LEDs
Power LED:
Located on the side towards the Reader Controller's field wiring.
A Red LED indicates 12VDC power is being supplied to the ASM.
Communication Status LED:
Located on the side towards the Lock wiring.
LED status meaning are described in the table below.
Reader
Reader
controller
controller
Locked
Unlocked
Off
Green
Flash Amber
Flash Amber
Off
Flash Amber
Off
Flash Amber
Off
Off
Wiring two readers to one lock
If you are wiring both sides of the door to control IN and OUT access, then
you will have the special condition of wiring two reader controllers to a
single locking mechanism.
The "Inside" Reader Controller controls the door, and is wired to the door's
components, such as the lock and door-sense switch. Use the following
steps to cause the "outside" Reader Controller to activate the REX input on
the "Inside" Reader Controller.
Steps
Figure 5.1: Two readers to one lock wiring
Î
1.
Wire the "Inside" reader normally
2.
Connect an ASM to the "Outside" reader
3.
Connect the "Inside" reader's REX input to the "NO" terminal of the
ASM.
4.
Connect the "Inside" reader's black wire to the Common terminal of the
ASM.
5.
If the door also has a REX device, wire the REX device "in parallel" to
the ASM.
Programming
"Inside" Reader Controller must be programmed to activate the lock upon a
REX input event.
19 • Schlage • Reader controller
Lock State when
Description or Item to Check
Reader controller
is unlocked
Normal Operation
No Operation
Yellow wire may be disconnected
No Operation
White wire may be disconnected
No Operation
Invalid encryption key received from Reader Controller
No Operation
If PowerCycle of Reader Controller allows for one or more lock
operations,and then the lock stops operating, then the BackEMF diode may
not be installed correctly.
Inside
ASM
Relay
remaining
wires
optional input REX
to remaining door
switch or relay
components
(dry contact)
Figure 5.1: Two readers to one lock wiring
Outside
ASM
control
Need help?
Do you have a question about the RC Pure IP and is the answer not in the manual?
Questions and answers