Wire Gauge Info - Aqua-Hot 400 Series Service Manual

Hide thumbs Also See for 400 Series:
Table of Contents

Advertisement

Wire Gauge Info

Interlock Switch
Wire Gauge Information:
Because all Aqua-Hot heating systems are designed to operate only when there is an adequate supply of DC
(Direct Current) voltage, it is imperative that the proper wire gauge be determined and used for the DC power
supply and ground wires. This section addresses how to determine the DC amperage draw of the heating
system, including heat exchangers, and how to determine the proper wire gauge based upon those fi ndings
for a specifi c application.
On the Front Side of the Aqua-Hot:
1. Review the chart above for the amperage draw of the Aqua-Hot heater
2. Determine the number of heat exchangers installed with the heating system.
3. Consult the heat exchanger's manufacturer for amp-draw information
NOTE: Each Aqua-Hot Cozy heat exchanger draws 0.23 amps of direct current.
Each Aqua-Hot Whisper heat exchanger draws 0.38 amps of direct current.
4. Determine the total amperage draw for all heat exchangers installed.
• For example, if six Aqua-Hot Cozy heat exchangers have been installed, multiply the
5. Add the total heat exchanger amperage draw to the amperage of the installed Aqua-Hot.
• For example, an Aqua-Hot 400P with six Cozy heat exchangers has a total amperage draw
p. 64
Aqua-Hot Model
400P
* Excludes heat exchangers
NOTE: Each heating zone "FAN" circuit can supply up to 2.0
amps of direct current.
amperage draw of each heat exchanger (0.23 amps) by the number of heat exchangers
(6). The total amperage draw in this scenario would be 1.38 amps.
of 20.38 amps.
©Aqua-Hot®
400P Service Manual
Base DC Amp Draw*
19 Amps

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ahe-400-p02

Table of Contents