Streamer Unit; Checking Procedures; Repair Procedures - Daikin Stylish Series Service Manual

Split r32
Hide thumbs Also See for Stylish Series:
Table of Contents

Advertisement

2
|
Components

2.15 Streamer unit

2.15.1 Checking procedures

2.15.2 Repair procedures

To remove the streamer unit
Service manual
112
1 As there is no specific check procedure for this component, first perform a
check of the indoor unit PCB to check if the streamer unit needs to be
replaced. See
"2.8.1 Checking
After complete check of the indoor unit
PCB, is the problem solved?
Yes
No
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Disconnect the streamer unit connector from the indoor unit PCB.
c
c
a Streamer unit connector
b Streamer unit
c Retainer
2 Route the streamer unit harness out of the retainers.
3 Click the streamer unit out of the indoor unit.
4 To install the streamer unit, see
4
procedures" [
Action
No further actions required.
Replace the streamer unit, see
"2.15.2 Repair
b
"2.15.2 Repair
(C)(F)TXA15~50A(W)(S)(T) + (C)(F)TXA15~50B(B)(S)(T) + RXA42+50A +
 71].
4
procedures" [
 112].
4
"2.13 Plate
work" [
 99].
a
4
procedures" [
 112].
RXA20~35A + RXA42+50B
ESIE18-03C – 2020.02
Split Stylish R32

Hide quick links:

Advertisement

Table of Contents
loading