Technical data

4.0 Technical data
Input:
Output:
Residual ripple:
Protection class:
Short circuit protection:
Surge voltage protection:
Overtemperature protection:
IP class:
Ambient temperature:
Weight:
Model
Item number
SMP301-01
702709739
SMP301-05
702709743
SMP301-02
702709741
SMP301-03
702709740
SMP301-04
702709742

5.0 Certificates

SMP301-M-DE-EN-FR-IT-NL-ES-01.pdf 22
SMP301-M-DE-EN-FR-IT-NL-ES-01.pdf 22
198-264 V AC / 50 Hz / 60 A max
12.7 V DC +/- 5% / 27 A
200 mV p-p at 25 ºC
II
yes
no
yes
IP20
-20 °C to +50 °C
~ 1 kg
SKU number
Output
Voltage
9106504722
350 W
12.7 V
9106505097
9106504643
350 W
12.7 V
9106504717
350 W
12.7 V
9106504929
350 W
12.7 V
10
Current
Design
intensity
with relay, bypass for external
27 A
12 V supply at the outputs F1,
F5
27 A
without relay, without bypass
with relay, without bypass, all
27 A
outputs are live for external
12 V supply
with relay, bypass for external
27 A
12 V supply at the output F1
22.02.2016 14:13:35