Hood body installation
• Before hooking up the Hood Canopy, lock the
2 Screws Vr located at the Hood Canopy con-
nection points.
• Hook up the Hood Canopy to the Screws 12r
taking care to ensure that the Safety brackets
7.5, fixed to the wall, enter the Side Housings
provided.
• Tighten the support Screws 12r until they lock.
• Adjust Screws Vr to level the Hood Canopy.
Connection in Ducting Version
When installing the ducting version, connect the
hood to the chimney using either a flexible or
rigid pipe ø 150 or 120 mm, the choice of which
is left to the installer.
To install a ø 150
• To install the dumper 10.
• Fix the pipe in position using sufficient pipe
clamps (not supplied).
To install a ø 120
• To install a ø 120 mm air exhaust connection,
insert the reducer flange 9 on the dumper 10.
• Fix the pipe in position using sufficient pipe
clamps (not supplied).
• Remove any activated charcoal filters.
Connection in Recycling Version
• Insert the connection extension pieces later-
ally 14.1 in connec-tion 15.
• Insert the Connector 15 into the Support
bracket 7.3 and fix it with a screw.
• Make sure that the outlet of the extension
pieces 14.1 is hori-zontally and vertically
aligned with the chimney outlets.
• Connect the air outlet connection 15 to the
hood body outlet using either a flexible or rigid
pipe ø 150 mm, the choice of which is left to
the installer.
• Ensure that the activated charcoal filters have
been inserted.
12r
ø 150
10
10
7.3
15
Vr
7.5
ø 120
9
14.1
ø 150