Download Print this page
Zamel exta WZH-01 Instruction Manual

Zamel exta WZH-01 Instruction Manual

Twilight switch

Advertisement

Quick Links

TWILIGHT SWITCH WZH - 01
DESCRIPTION
The twilight switch WZH-01 is used
to control lighting devices and other
energy receivers depending on luminous
flux density. The system switches on the
lighting at dusk and switches off at dawn.
The switching on threshold can be adju-
sted by the user. The system is resistant
to momentary changes of luminous flux
density and the same guarantees its relia-
bility. The hermetic casing (IP65) secures
the device functioning in unfavorable we-
ather conditions.
FEATURES
‫ ی‬It allows to switch on and/or switch off
lighting devices according to the pre-
set ambient light level,
‫ ی‬adjustment of the switch on threshold,
‫ ی‬wide setting scope of the switch on
threshold (from 0 to 200 lx),
‫ ی‬inner lighting sensor,
‫ ی‬resistant to momentary changes of lu-
minous flux density,
‫ ی‬hysteresis of the switch-over thres-
hold,
‫ ی‬hermetic (IP65 protection degree) en-
closure,
‫ ی‬voltage relay output max 16 A capaci-
ty.
The device is designed
for one-phase installa-
tion and must be instal-
led in accordance with
standards valid in a par-
CAUTION
ticular country. The devi-
ce should be connected
according to the details included in this
operating manual. Installation, connection
and control should be carried out by a qua-
lified electrician staff, who act in accordan-
ce with the service manual and the device
functions. Disassembling of the device is
equal with a loss of guarantee and can
cause electric shock. Before installation
make sure the connection cables are not
under voltage. The cruciform head screw-
driver 3,5 mm should be used to instal
the device. Improper transport, storage,
and use of the device influence its wrong
functioning. It is not advisable to instal the
device in the following cases: if any device
part is missing or the device is damaged or
deformed. In case of improper functioning
of the device contact the producer.
Zakład Mechaniki i Elektroniki
ZAMEL sp.j.
J.W. Dzida, K. Łodzińska
Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamel.pl, e-mail: marketing@zamel.pl
TECHNICAL PARAMETERS
Power supply cables: L (black), N (blue)
Input rated voltage: 230 V~
Input voltage tolerance: from -15 to +10 %
Nominal frequency: 50 / 60 Hz
Rated power consumption: 24 mA
Output (load) cables: L (brown) , N (grey)
Threshold adjustment range: from 0 to 200 lx (potentiometer)
Output relay parameters: 1NO-16 A / 250 V AC1 4000 VA (voltage contact)
Number of switch cables: 4
Section of connecting cables: 4x 1,50 mm
Length of connecting cables: 0,5 m
Ambient temperature range: from -20 to +45
Operating position: vertically, cable down
Protection level of casing: IP65 (EN 60529)
Overvoltage category: II
Rated impulse withstand voltage: 1 kV (EN 61000-4-5)
Reference standards: EN 60669-1
APPEARANCE
INSTRUCTION MANUAL
WZH - 01
Lighting sensor: inner
2
Mounting: 2x stretcher 5x(3x30)
Protective class: II
Pollution degree: 2
Dimensions: 69x56x27 mm
Weight: 104 g
EN 60669-2-1
EN 61000-4-2,3,4,5,6,11
Inner lighting sensor
Adjustment of the switch on threshold
Power supply cable (L)
Power supply cable (N)
Output (load) cable (N)
Output (load) cable (L)
C
o
ver. 0.4.1 _ 2006.06.27_14:00

Advertisement

loading

Summary of Contents for Zamel exta WZH-01

  • Page 1 Zakład Mechaniki i Elektroniki ZAMEL sp.j. J.W. Dzida, K. Łodzińska Zielona 27, 43-200 Pszczyna, Poland Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04 www.zamel.pl, e-mail: marketing@zamel.pl DESCRIPTION TECHNICAL PARAMETERS The twilight switch WZH-01 is used WZH - 01 to control lighting devices and other...