  • Page 3 GOLD QUICK GUIDE DESCRIPTION OF THE SET 1.1. RECEIVER POSITION OF THE HOLES FOR FIXATION MAGRGOLDGB-REV.3-16/02/05 - M.E.C. Approved by Engineering Manager: J. Varela.
  • Page 4: Configuration Of The Receiver

    GOLD QUICK GUIDE 1.1.1. CONFIGURATION OF THE RECEIVER A (Pos. OFF) ZERO The Zero Point. relay is activated when any command is activated. AUXILIARY Auxiliary relay enabled. A (Pos. ON) INDEPENDENT SPEEDS Changes the common second speeds configuration to independent (Fig. 2). Options C and D are not available in this mode.
  • Page 5: Relay Outputs

    GOLD QUICK GUIDE 1.1.2. RELAY OUTPUTS RELAIS 1 RAISE RELAIS 2 LOWER RELAIS 3 TROLLEY LEFT RELAIS 4 TROLLEY RIGHT RELAIS 5 CRANE FORWARDS RELAIS 6 CRANE BACKWARDS RELAIS 7 2nd SPEED HOISTING RELAIS 8 RELAIS 9 2nd SPEED TROLLEY...
  • Page 6 GOLD QUICK GUIDE RELAIS 1 RAISE RELAIS 2 LOWER RELAIS 3 TROLLEY LEFT RELAIS 4 TROLLEY RIGHT RELAIS 5 CRANE FORWARDS RELAIS 6 CRANE BACKWARDS RELAIS 7 2nd SPEED RAISE RELAIS 8 2nd SPEED LOWER RELAIS 9 2nd SPEED TROLLEY RIGHT...
  • Page 7 GOLD QUICK GUIDE RELAIS 1 RAISE RELAIS 2 LOWER RELAIS 3 TROLLEY LEFT RELAIS 4 TROLLEY RIGHT RELAIS 5 CRANE FORWARDS RELAIS 6 CRANE BACKWARDS RELAIS 7 2nd SPEED RAISE RELAIS 8 2nd SPEED LOWER RELAIS 9 2nd SPEED TROLLEY...
  • Page 8 GOLD QUICK GUIDE 1.1.3. MESSAGES OF THE RECEIVER • NORMAL OPERATION RELAY POWER RELAY POWER FAILURE Rx OK FAILURE Rx OK FUNCIONANDO FALLO ALIMENT. Rx OK FUNCIONANDO FALLO ALIMENT. Rx OK RELE RELE When switched on, all the leds, Signal reception OK...
  • Page 9: Power Supply Fault

    GOLD QUICK GUIDE • CHANGING THE FREQUENCY RELAY POWER RELAY POWER FAILURE Rx OK FAILURE Rx OK FUNCIONANDO FALLO ALIMENT. Rx OK FUNCIONANDO FALLO ALIMENT. Rx OK RELE RELE Receiver stand-by Frequency change OK frequency change • ANOMALIES RELAY POWER...
  • Page 10 GOLD QUICK GUIDE 1.1.4. RECORDING THE KEY FROM THE RECEIVER To match the transmitter and the receiver, the key is removed from the transmitter and is inserted in the slot of the receiver controller next to the minidips. Depending on how the key is recorded, the corresponding message will appear (see section Receiver Messages).
  • Page 11: Operation Sequence

    GOLD QUICK GUIDE 1.2. TRANSMITTER 1.2.1. OPERATION SEQUENCE With the battery and key inserted: Unlock the E-STOP Press the start button ATTENTION!: IF THE BATTERY OR KEY HAS BEEN REMOVED, THE STOP BUTTON MUST BE PRESSED AND RELEASED IN ORDER TO ACTIVATE THE SET.
  • Page 12: Transmitter Configuration

    GOLD QUICK GUIDE 1.2.2. TRANSMITTER CONFIGURATION With the battery inserted: • CHANGE AUTOMATIC DISCONNECTION TIME EMERGENCY STOP With the emergency stop locked, insert the key and press RAISE and CRANE NORTH buttons at the same time and keep them pressed.
  • Page 13: During Transmission

    GOLD QUICK GUIDE 1.2.3. TRANSMITTER MESSAGES INFORMATION Control in stand-by. Stop button is released, but 1 flash every 8 sec. the START button is off. Transmission mode OK Battery OK 1 sec. on DURING TRANSMISSION 1 sec. off Low battery (it does not work with the set on stand-by).
  • Page 14: Changing The Frequency

    GOLD QUICK GUIDE CHANGING THE FREQUENCY 1.3. CHANGING THE FREQUENCY CHANGE MODE Remove the key (the E-STOP should be unlocked) Press the ON and UNIT button at the same time and keep them pressed. Insert the key The led will indicate the current frequency change mode...
  • Page 15 GOLD QUICK GUIDE ATTENTION!: WHEN USING THE SET FOR FIRST TIME OR WHEN PROGRAMMING THE KEY, BEAR IN MIND THAT IT ALWAYS LEAVES THE EQUIPMENT IN AUTOMATIC FREQUENCY CHANGE MODE. 1.4. FREQUENCY CHANGE MODES 1.4.1. DISABLED The frequency cannot be changed in this mode.
  • Page 16 GOLD QUICK GUIDE 1.4.3. AUTOMATIC Press START and keep it pressed, lock the E-STOP. The set will automatically change to another channel. ATTENTION!: IF THE SET DOES NOT START UP AFTER CHANGING A FREQUENCY, KEEP THE START BUTTON PRESSED UNTIL THE RELAYS ARE ACTIVATED (MAX.
  • Page 17 GOLD QUICK GUIDE 1.5. TABLE OF FREQUENCIES Channel Frequen. Channel Frequen. Channel Frequen. Channel Frequen. 868.000 868.550 869.100 869.650 868.025 868.575 869.125 869.675 868.050 868.600 869.150 869.700 868.075 868.625 869.175 869.725 868.100 868.650 869.200 869.750 868.125 868.675 869.225 869.775 868.150 868.700...
  • Page 18 GOLD QUICK GUIDE CHARGER 1.6. MESSAGES OF THE CHARGER Va000782 Fig. 6. Charger INFORMATION No connection to the transmitter or to the power supply. Charging finished Normal charge Incorrect charge: Battery in bad condition Flashing Unnormal temperature conditions Pre-charging status...
  • Page 19 GOLD QUICK GUIDE...
  • Page 21: Useful Addresses

    ANSATGB Rev. 2 USEFUL ADDRESSES ITOWA S.A.U. C/ Faraday, 159 08224 TERRASSA (BARCELONA) Telf +34-93.733.98.50 Fax +34-93.789.13.51 e-mail: info@itowa.com http://www.itowa.com...
  • Page 23: Ec Declaration Of Conformity

    DCGOLDGB – Rev. 1 EC – DECLARATION OF CONFORMITY The manufacturer: ITOWA S.A C/ Faraday, 159 E-08224 Terrassa Barcelona, España Tel.: +34 93 733 98 50 Fax: +34 93 789 13 51 According with the requirements of the R&TTE 1999/05/EC Annex III declares under its...
  • Page 25 Equipment’s guarantee includes both the replacement or repair of defective elements as well a labour. Guarantee is valid with the units placed at ITOWA’s facilities in Terrassa, Spain. Coverage of this guarantee will not be valid under the following circumstances: •...