Operating Instructions; Status Indicator - Delta AC MAX Installation And Operation Manual

Table of Contents

Advertisement

Operating Instructions

Basic Version
o n
o ff
o n
o ff
Figure 15. Enabling the Charging Function

Status Indicator

Status
Black
Yellow, fast flashing
Blue
Yellow
Blue, slow flashing
Green
Red, slow flashing
Red
Fault Event
Status
High/under voltage
Red, 1 Flash
protection
Red, 2 Flashes
Ground fault protection.
Ground does not correctly
Red, 3 Flashes
connect to the charger.
Red, 4 Flashes
Over current protection.
Over temperature
Red, 5 Flashes
protection.
Red, 6 Flashes
Input mis-wired.
Red, 7 Flashes
Control pilot signal error.
Installation and Operation Manual
Power off.
Initial configuration and self-test.
Standby mode (not connecting to EV).
Ready to charge (connecting to EV).
Charging in progress.
Charging process completed.
Refer to fault event.
Self-test failed. Please contact Customer Support.
Description
Installation and Operating Instructions
The key switch is located on the side of the
product. Charger is powered on when the key
switch is in the On position.
Description
The charger will be auto-recovery once the voltage is
normal. If not, please restart the charger or contact
Customer Support.
Check the ground system, and wait for recovery.
Check if ground (PE) is well connected.
Unplug the charging connector and plug it again.
Wait for recovery and check if any heat source around
the charger. If yes, please try to remove the heat source.
Swap the Line (L) and Neutral (N).
Please contact Customer Support.