Heating actuator for up to 4 outputs 230VAC
ZCL-4HT230
FEATURES
4 configurable outputs for 230VAC valve control.
4 thermostats.
10 logic functions.
Total data saving on KNX bus failure.
Manual control through buttons and status LED indicators.
Common 230VAC supply required for the 4 outputs.
Integrated KNX BCU.
Dimensions 67 x 90 x 35mm (2 DIN units).
DIN rail mounting (EN 50022), through pressure.
Conformity with the CE directives (CE-mark on the right side).
1. 230V input (live phase)
5. Programming/Test LED
Programming/test button: short press to set programming mode. If this button is held while plugging the device into the KNX bus, it enters the safe
mode. If this button is held for more than 3 seconds, the device enters the test mode.
Programming/Test LED: programming mode indicator (red). When the device enters the safe mode, it blinks (red) every half second. The manual mode
is indicated by the green color. During the start-up (reset or after KNX bus failure) and if the device is not in safe mode, it emits a red flash.
GENERAL SPECIFICATIONS
CONCEPT
Type of device
Voltage (typical)
Voltage range
KNX supply
Maximum
consumption
Connection type
External power supply
Operation temperature
Storage temperature
Operation humidity
Storage humidity
Complementary characteristics
Protection class
Operation type
Device action type
Electrical stress period
Degree of protection
Installation
Minimum clearances
Response on KNX bus failure
Response on KNX bus restart
Operation indicator
Weight
PCB CTI index
Housing material
¹ Maximum consumption in the worst case scenario (KNX Fan-In model)
© Zennio Avance y Tecnología S.L.
2. Valve outputs
6. Programming/Test button
Voltage
29VDC (typical)
24VDC¹
Edition 3
6
3. Output control button
DESCRIPTION
Electric operation control device
29VDC SELV
21..31VDC
mA
7.5
10
Typical TP1 bus connector for 0.80mm Ø rigid cable
230V 50/60Hz (only phase, for valve supply)
0°C .. +55°C
-20°C .. +55°C
5 .. 95% (No condens.)
5 .. 95% (No condens.)
Class B
II
Continuous operation
Type 1
Long
IP20, clean environment
Independent device to be mounted inside electrical panels with DIN rail (EN
50022)
Not required
Data saving according to parameterization
Data recovery according to parameterization
The programming LED indicates programming mode (red) and test mode
(green). Each output LED indicates its status (fixed=active output;
flashing=overload or short-circuit). The blue blinking of the programming
LED indicates a 3 minutes lock due to the suffering of 3 short-circuits in less
than 3 minutes.
98g
175V
PC FR V0 halogen free
Futher information
HeatingBOX 230V 4X
TECHNICAL DOCUMENTATION
1
4
3
Figure 1: HeatingBOX 230V 4X
4. Output status Indicator LED
7. KNX connector
mW
217.5
240
www.zennio.com
2
5
7
Page 1/2

Advertisement

loading

Summary of Contents for Zennio HeatingBOX 230V 4X

  • Page 1 • DIN rail mounting (EN 50022), through pressure. • Conformity with the CE directives (CE-mark on the right side). Figure 1: HeatingBOX 230V 4X 1. 230V input (live phase) 2. Valve outputs 3. Output control button 4. Output status Indicator LED 5.
  • Page 2 230VAC 50/60Hz Figure 2: Wiring example: several valves per output and one valve per output. Attaching HeatingBOX 230V 4X to DIN rail: Removing HeatingBOX 230V 4X from DIN rail: Figure 3: Mounting HeatingBOX 230V 4X on DIN rail SAFETY INSTRUCTIONS •...

This manual is also suitable for:

Zcl-4ht230