Troubleshooting; Disposal - Dometic BordBar TB 15 Operating Manual

Thermoelectric cooler
Hide thumbs Also See for BordBar TB 15:
Table of Contents

Advertisement

Troubleshooting

10
Troubleshooting
Fault
Your cooler does not
work (plug is inserted).
The cooler does not cool
(plug is inserted).
Operation with a 12 V
socket:
The ignition is on and the
cooler is not working.
11

Disposal

➤ Place the packaging material in the appropriate recycling waste bins wherever
possible.
M
If you wish to finally dispose of the product, ask your local recycling centre
or specialist dealer for details about how to do this in accordance with the
applicable disposal regulations.
12
Possible cause
There is no voltage
flowing from the 12 V
socket in your vehicle.
The inner fan or the
cooling element is
defective.
The cigarette lighter
socket is dirty. This
results in a poor
electrical contact.
The fuse of the 12 V
plug has blown.
The vehicle fuse has
blown.
Autogoods "130"
Suggested remedy
The ignition must be switched on in
most vehicles for voltage to flow at the
cigarette lighter.
This can only be repaired by an
authorised customer services unit.
If the plug of your cooler becomes very
warm in the cigarette lighter socket,
either the socket must be cleaned or
the plug has not been assembled
correctly.
Replace the fuse (5 A) in the 12 V plug
(fig. 3, page 4).
Replace the vehicle's 12 V socket fuse
(usually 15 A). (Please refer to the
operating manual of your vehicle.)
BordBar TB15
EN