Danfoss EKC 201 Instructions Manual page 4

Advertisement

Available languages

Available languages

Quick Guide
Initial
What
controller
to do
setup
What the controller does automatically
Normal
Read
operation
or
change
room
Room
Room
temp.
temp.
temp. 1
setting
Normal
Read
Code
operation
or change
(or alarm)
parameter
Room
codes
Change
Unknown
temp.
and
codes
settings
and settings
Re-establish
Unknown
Room
all factory
Power off
settings
temp.
settings
Read
Normal
defrost
Room
operation
temp.
sensor
or alarm
temp.
Manually
start of
Normal
Room
a defrost
operation
temp.
operation
Manually
stop of
Defrost
Room
a defrost
operation
temp.
operation
Reset
Alarm
Room
alarm
relay
temp.
relay
activated
Alarm relay
Read codes
Room
cause of
not
temp.
alarm mode
activated
1
) The compressor relay closes when the room temperature exceeds the setting value and differential.
2
) Alarm is released and sensor failure is indicated, if the room temperature reaches 5°C or more outside the setting range
–60° to +50°C.
3)
The frequency is measured after approx. three days and nights operation after start of the plant (72 cyclings) otherwise:
ON-time = c03 × 20: 100 minutes
OFF-time interval 20 minus ON-time per minute
4
) Function possibilities with SPST contact, connected to the terminals 3 and 4 are the following:
Door alarm : If SPST is cut out, alarm signalling starts and the fan is stopped, cf. A04 or F02.
Defrost: If SPST is cut in, defrost starts.
(However, if d03 is not OFF, defrost will during contact break down start with the programmed time intervalles).
Bus : With installed communication card, the position of the SPST contacts will be registered in the BUS system.
Operating the two pushbuttons
Display
controller
readout
Set
Room
value
temp.
Room
Change
temp.
Set
value
(or alarm)
Room
Change
temp.
and settings
All parameter
Power
Room
on
temp.
Room
Defrost sensor temp.
temp.
Defrost operation
Room
temp.
Room temp.
Room
Room temp.
temp.
Alarm relay
Alarm code/
Room
Fault code
temp.
Alarm code/
Room
Fault code
temp.
Controller application setting parameters
Resulting
Setting and read-off parameters
setup
Temperature controller, Temperature
Thermostat
Differential
1
)
Normal
Max. limitation of set temperature
operation
Min. limitation of set temperature
Adjustment of temperature indication
Temperature unit (°C/°F)
Room
Alarm
temp. 2
Upper deviation (above temp. setting + differential
Lower deviation (below temp. setting
Normal
Temperature alarm delay
operation
Door alarm delay
Compressor
Min. ON-time
Known
Min. OFF-time
3
codes
Cut-in frequency on sensor fault
)
Compressor stop at open door (yes/no)
Defrost
Defrost method (EL/GAS)
Defrost stop temperature
settings
Interval between defrost starts
= factory
Max. defrost duration
settings
Defrost time delay (after power up)
Drip-off time
Normal
Fan start delay after defrost
operation
Fan start temperature
Fan cut-in during defrost (yes/no)
Defrost sensor (yes/no)
Temperature alarm delay after defrost
Delay of display view after defrost stop
Normal
Fan
operation
Fan stop on compressor cut-out (yes/no)
Fan stop delay
Fan stop at open door (yes/no)
Miscellaneous
Normal
Delay of output signal after start-up
operation
4
Digital input signals
)
(0 = not used, 1 = door alarm, 2 = defrost, 3 = bus)
Access code
Used sensor type (Pt / PTC)
Real time clock (if fitted)
not
Six start times for defrost
activated
All can be cut out by setting on OFF
Hour setting
Alarm
Minute setting
Fault code display
E 1
Fault in controller
E 2
Disconnected room sensor
E 3
Short-circuited room sensor
E 4
Disconnected defrost sensor
E 5
Short-circuited defrost sensor
E 6
Change battery
Para-
Controller
meter
application no.
codes
1
2
3
r01
r02
r03
r04
r05
2
)
A01
2
)
A02
A03
A04
c01
c02
c03
c04
d01
d02
d03
d04
d05
d06
d07
d08
d09
d10
d11
d12
F01
F02
F03
o01
o02
o05
o06
t01→ t06
t07
t08
Alarm code display
A 1
High temperature alarm
A 2
Low temperature alarm
A 4
Door alarm
Min.
Max.
Factory
Actual
value
value
setting
setting
4
-60
o
C
50
o
C
3
o
C
0.1 K
20 K
2 K
-59
o
C
50
o
C
50
o
C
-60
o
C
49
o
C
-60
o
C
20 K
20 K
0.0 K
o
C
0 K
50 K
10 K
50 K
0 K
10 K
0 min
90 min
30 min
0 min
90 min
60 min
0 min
15 min
0 min
0 min
15 min
0 min
0 %
100 %
0 %
no
EL
0
o
C
25
o
C
6
o
C
OFF
48 hour
8 hour
0 min
180 min
45 min
0 min
60 min
0 min
0 min
20 min
0 min
0 min
20 min
1 min
-15
o
C
0
o
C
-5
o
C
no
yes
0 min
199 min
90 min
0 min
15 min
1 min
no
0 min
30 min
0 min
yes
0 s
600 s
5 s
0
OFF
100
OFF
Pt
0
23
OFF
0 hour
23 hour
0 hour
0 min
59 min
0 min
Status code display
S 2
ON-time
S 3
OFF-time
S 4
Drip-off time

Advertisement

loading

This manual is also suitable for:

Ekc 301