Page 1
SARA-R4 series cellular evaluation kits User guide Abstract This guide explains how to set up the EVK-R4 evaluation kits to begin evaluating the u-blox SARA-R4 series cellular modules supporting multi-band LTE-M / NB-IoT / EGPRS radio access technology. UBX-16029216 - R07 C1-Public www.u-blox.com...
The information contained herein is provided “as is” and u-blox assumes no liability for its use. No warranty, either express or implied, is given, including but not limited to, with respect to the accuracy, correctness, reliability and fitness for a particular purpose of the information.
EVK-R4 - User guide Contents Document information ..........................2 Contents ................................3 Starting up ............................... 4 Appendix ............................... 18 Setting up AT terminal applications for communication with the EVK-R4 ....18 Setting up a cellular packet data connection on a Windows PC ......... 19 Examples of AT commands ......................
Starting up 1.1 EVK-R4 overview The EVK-R4 kit is a powerful and easy-to-use tool that simplifies the evaluation of the u-blox SARA-R4 series multi-band LTE-M / NB-IoT / EGPRS cellular modules. The following evaluation kits are available with u-blox SARA-R4 cellular modules: •...
Page 5
EVK-R4 - User guide Cellular RS232 Cellular USB NEO-M8N GNSS 9 – 18 V (UART) (UART) antenna connector Power input J500 J208 J501 J400 DS118 GNSS USB DS124 J102 DL405 DL403 DL501 SW300 DL404 GNSS adapter board Main power switch SW400 NEO-M8N DL401...
Page 6
EVK-R4 - User guide Cellular RS232 Cellular USB 9 – 18 V NEO-M8N GNSS (UART) (UART) Power input antenna connector J500 J501 J208 J400 DS118 GNSS USB DL405 DL403 DL501 DS124 J102 SW300 DL404 GNSS adapter board Main power switch SW400 NEO-M8N DL401...
Page 7
EVK-R4 - User guide Cellular RS232 NEO-M8N GNSS Cellular USB antenna connector (Single UART) (Single UART) 9 – 18 V J500 J208 J501 Power input J400 GNSS USB DL403 DL501 J102 DL405 SW300 GNSS DS124 DS118 adapter board DL404 Main power switch NEO-M8N SW400 GNSS module...
Page 8
USB interface of the SARA-R4 module, and the DIL header connectors (J300 and J301) making accessible interfaces of the SARA-R4 module. The GNSS adapter board, called ADP-GNSS, contains the u-blox NEO-M8N GNSS module, the GNSS antenna connector and the USB connector for the u-blox NEO-M8N GNSS module.
Page 9
The lower board (EVB-WL3) is designed to also be used with other u-blox cellular adapter boards. It contains additional switches, jumpers, connectors, LEDs and parts that are only partially described in...
Page 10
EVK-R4 - User guide 1.3 Switches, jumpers and buttons Description Board Function Name Main power switch Power on / off of the whole evaluation kit SW400 Cellular VCC Jumper socket to provide the 3.8 V supply to the cellular module VCC input J404 J109 ADP-R42...
Page 11
EVK-R4 - User guide Function Description LED # Board Color Cellular USB USB cable plugged in the Cellular USB connector (J201) on the DS201 ADP-R42 (two UARTs) ADP-R4, for access to the two UART interfaces of SARA-R422M8S GNSS VCC supply NEO-M8N GNSS module supply is turned ON DS118 ADP-GNSS GNSS USB...
Page 12
EVK-R4 - User guide 1.6 EVK-R410M pin out SARA-R410M DIL B2B SARA-R410M DIL B2B Pin N° Name Name / Pin N° Pin N° Name Name / Pin N° J301 pins 7-8-9-10 RSVD Not available RSVD J301 pin 3 I2S_WA Not available J301 pins 7-8-9-10 I2S_TXD Not available...
Page 13
EVK-R4 - User guide 1.7 EVK-R412M pinout SARA-R412M DIL B2B SARA-R412M DIL B2B Pin N° Name Name / Pin N° Pin N° Name Name / Pin N° J301 pins 7-8-9-10 RSVD Not available RSVD J301 pin 3 I2S_WA Not available J301 pins 7-8-9-10 I2S_TXD Not available...
Page 14
EVK-R4 - User guide 1.8 EVK-R422M8S pinout SARA-R422M8S DIL B2B connector SARA-R422M8S DIL B2B connector Pin no. Signal name Name / pin number Pin no. Signal name Name / pin number J301 pins 7-8-9-10 RSVD J301 pin 36 USB_3V3 J301 pin 4 I2S_WA J300 pin 26 J301 pins 7-8-9-10...
Page 15
The USB drivers for Windows operating systems are available with the EVK-R4. Executable files can be downloaded from www.u-blox.com/evk-downloads and saved to any location on the computer hard drive. The installation can be started by running the executable file on a computer with the Windows operating system.
Page 16
UARTs detached from mini USB (J501) and RS232 (J500) connectors on EVB-WL3 Table 7: Serial interface configuration Run an AT terminal application (e.g. the u-blox m-center tool), and select the AT COM port with the following settings: Data rate: 115,200 bit/s...
Page 17
EVK-R4 - User guide 1.11 Enabling error result codes Command sent by DTE (user) DCE response (module) Description AT+CMEE=2 Enables the cellular module to report verbose error result codes. 1.12 PIN code insertion (when required) Command sent by DTE (user) DCE response (module) Description AT+CPIN="8180"...
SARA-R4 series AT commands manual [1]. Figure 8: AT terminal window For more information on using the u-blox m-center cellular module evaluation tool, press the F1 key on the keyboard to open the m-center help window on the computer. UBX-16029216 - R07...
EVK-R4 - User guide B Setting up a cellular packet data connection on a Windows PC This section describes how to set up a packet data connection with the Windows 7 operating systems (for PC) and EVK-R4, using the TCP/IP stack of the PC (external TCP/IP stack). The following examples describe how to install and configure two different kinds of modem on Windows: Over the UART interface of the cellular module: connect the Windows PC to the Cellular USB...
Page 20
EVK-R4 - User guide Set the COM port on which the modem will be installed. From “Device Manager”> Modems > Standard Modem 33,600 bps Modem #X (X is the assigned modem number) right click and select “Properties”. Select the “Advanced” tab. Add in the “Extra initialization commands”...
Page 21
EVK-R4 - User guide 12. Select the modem, if requested (the question appears only if more than one modem is available). 13. Enter parameters for dial-up connection: The module telephone number (*99***1#) The specific account information for the network operator (if needed) A name for the new connection 14.
Page 22
EVK-R4 - User guide B.2 How to install and configure a modem data connection over ☞ Section applicable to EVK-R410M and EVK-R412M only. This example describes how to install and configure a data connection on a PC with the Windows 7 operating system using the TCP/IP stack of the PC, over the native USB interface of the SARA-R410M and SARA-R412M modules connected to the Windows PC by the Cellular Native USB connector (J105 on the ADP).
Page 23
EVK-R4 - User guide Select Qualcomm HS-USB Modem 90B2 #X (X=11 in the picture) Enter the modem telephone number (*99***1#), select Allow other people to use this connection. ☞ Consult the cellular mobile network operator for the username and the password.
For the complete description and syntax of the AT commands supported by SARA-R4 series cellular modules, see the u-blox SARA-R4 series AT commands manual [1]. For detailed examples of AT commands used for common operations, see the u-blox SARA-R41 series application development guide and the u-blox SARA-R42 series application development guide [5].
Page 25
EVK-R4 - User guide C.3 Opening a UDP socket Command sent by DTE (user) DCE response (module) Description AT+CMEE=2 Enables the cellular module to report verbose error result codes. AT+CGATT? +CGATT: 1 Verifies the SARA-R4 module is attached to the network. AT+CEREG? +CEREG: 0,1 Verify the network registration status.
EVK-R4 - User guide D Current consumption measurement D.1 EVK-R410M and EVK-R412M The current consumption of the SARA-R410M and SARA-R412M modules can be measured on the EVK-R4 by removing the jumper socket from the Cellular VCC supply jumper J404 available on the EVB-WL3 as illustrated in Figure Cellular VCC supply jumper socket (J404)
Page 27
EVK-R4 - User guide D.2 EVK-R422M8S The current consumption of the SARA-R422M8S modules can be measured on the EVK-R4 by removing the jumper socket from the Cellular VCC supply jumper J109 available on the ADP-R4, as illustrated in Figure Cellular VCC supply jumper socket (J109) to be removed for SARA-R422M8S module current consumption measurements Figure 12: Jumper socket to be removed for SARA-R422M8S modules current consumption measurement...
EVK-R4 - User guide E Glossary Abbreviation Definition Alternating current Adapter Board AT Command Interpreter Software Subsystem, or attention Board-To-Board Clear To Send Direct Current Data Carrier Detect Data Communication Equipment Direct Current Display Data Channel interface Dual In Line DSC transponder response DTE, TE Data Terminal Equipment...
(petrol stations, refineries…). Any changes or modification made to this equipment will void its compliance to the safety requirements. Maintenance, inspections and/or repairs of the EVK-R4 shall be performed by u-blox AG. UBX-16029216 - R07 Appendix...
UBX-18019856 u-blox SARA-R42 series application development guide, UBX-20050829 All these documents are available on our website (http://www.u-blox.com). ☞ For regular updates to u-blox documentation and to receive product change notifications, register on our homepage (www.u-blox.com). Revision history Revision Date Name...
EVK-R4 - User guide Contact For complete contact information, visit us at www.u-blox.com. u-blox Offices North, Central and South America Headquarters Asia, Australia, Pacific Europe, Middle East, Africa u-blox America, Inc. u-blox Singapore Pte. Ltd. u-blox AG Phone: +1 703 483 3180...