OMEGA AIR WOS Installation And Operating Manual

OMEGA AIR WOS Installation And Operating Manual

Water-oil separator

Advertisement

Quick Links

Installation and operating
manual
WOS water-oil separator
Please read the following instructions carefully before installing separator unit into service.
Trouble free and safe operating of the unit can only be guaranteed if recommendations and
conditions stated in this manual are respected.
3400328-WOS_v1.03-OmegaAir_eng_ver10072012

Advertisement

Table of Contents
loading

Summary of Contents for OMEGA AIR WOS

  • Page 1 Installation and operating manual WOS water-oil separator Please read the following instructions carefully before installing separator unit into service. Trouble free and safe operating of the unit can only be guaranteed if recommendations and conditions stated in this manual are respected.
  • Page 2 WOS - Installation and operating manual Components Water Part Inlet connection- condensate (water, oil) Depressurization chamber (with air filter) First stage chamber Condensate flow Oil filter cartridge Condensate flow (water, residual oil traces) Activated carbon filter cartridge (final oil elimination) Clean water outlet (residual oil content <10ppm...
  • Page 3: Technical Data

    WOS - Installation and operating manual Technical data Cold climate zone Mild climate zone Hot climate zone Size 15°C 60%RH 25°C 60%RH 40°C 100%RH 2,89 2,43 1,23 Max oil adsorption[kg] WOS-4 4,82/170,22 4,04/142,80 2,05/72,32 Max FAD [Nm /min]/[scfm] Max condensate flow [l/h]...
  • Page 4: Safety Instructions

    WOS - Installation and operating manual Safety instructions The relevant safety at work and accident prevention regulations, plus operating instructions, shall apply for operating the separator. The separator has been constructed in accordance with the generally recognized rules of engineering.
  • Page 5: Appropriate Use

    WOS - Installation and operating manual Appropriate use WOS water oil separators are intended for separating lubricant oil from condensate from compressed air systems. This appliance must be used only for the purpose for which it was specifically designed. All other uses are to be considered incorrect.
  • Page 6: Installation

    WOS - Installation and operating manual Installation · Unpack the device · It is recommended to place the device near the wall. Test valve is located on front side of the device. · Make sure that you have easy access to the front side of the device.
  • Page 7: Maintenance

    WOS - Installation and operating manual Maintenance It is rec ommended, that you do a check once per week to evaluate filter element saturation. To test water quality use test set. Instructions are attached in test set. Filter element must be replaced when first of the following parameters appears: ·...
  • Page 8 WOS - Installation and operating manual OMEGA AIR d.o.o. Ljubljana Cesta Dolomitskega odreda 10 SI-1000 Ljubljana, Slovenia Tel.: +386 (0)1 200 68 00 Fax.: +386 (0)1 200 68 50 E-mail: info@omega-air.si www.omega-air.si...

This manual is also suitable for:

Wos-4Wos-8Wos-20Wos-35

Table of Contents