REMOTE HYDRAULIC CONTROL SYSTEM
(1) Remote control valve (1)
with flow control
(2) Remote control valve (2)
with flow control
(3) Flow control knob for valve
(1)
Adjusting the flow rate
1. The flow rate for the remote control valves (1) and
(2) can be adjusted.
2. Turn the flow control knobs (3) and/or (4)
counterclockwise (A), and the flow rate for the
remote control valves (1) and/or (2) increases. A
clockwise turn (B) of the knob causes the flow to
decrease. If the knob is turned all the way (C), there
will be no flow.
3. To adjust the flow rate, set the engine speed to the
operating RPM, turn the flow control knob once all
the way clockwise (C), and then turn it gradually
counterclockwise until a required flow rate is
reached.
NOTE :
• Oil from the pump flows by priority to the
auxiliary control valve. Surplus oil is fed to
the 3-point hitch. With the auxiliary control
valve at neutral, the total flow from the
pump is fed to the 3-point hitch.
IMPORTANT :
• When there is no need to adjust the flow
rate, turn the flow control knob all the way
counterclockwise
position.
M4N-071, M5N-091, M5N-111
(4) Flow control knob for valve
(2)
and
keep
it
in
this
(1) Remote control valve (1)
with flow control
(2) Remote control valve (2)
with flow control
(3) Flow control knob for valve
(1)
 HYDRAULIC UNIT
(4) Flow control knob for valve
(2)
(A) "INCREASE"
(B) "DECREASE"
(C) "STOP"