Specifications; After-Sales Service - Mitsubishi Electric VL-250CZPVU-R-E Instruction Manual

Lossnay heat recovery ventilator (residential use)
Hide thumbs Also See for VL-250CZPVU-R-E:
Table of Contents

Advertisement

8. Specifications

Model
Electrical power supply
Erp Class
Ventilation mode
Fan speed
Fan power
Input power
Air volume
External static pressure [Pa]
Temperature exchange efficiency [%]
Noise (Sound pressure level *
Weight [kg]
- The above values are at factory default setting.
- The current, power consumption, efficiency, and noise are measured at the rated air volume and at 230 V / 50 Hz.
- Contact your dealer for other specifications.
1
*
The sound pressure level at 3 m is spherical.
9. After-Sales Service
Consult with your dealer about the after-sales services
provided for the product.
■ Retention period of functional repair parts
We will retain the functional repair parts for 6 years after terminating production of the product.
The functional repair part means a part which is necessary to maintain the function of the product.
■ Recommended inspection and maintenance
After several years of use, the following might occur. We recommend inspection and maintenance by a
professional.
- Water leakage due to clogging of drain pipe and drain hose
- Entry of dust due to deterioration of filters
- Abnormal noise or vibration due to the motor reaching the end of its service life
- Air leakage due to the heat exchanger reaching the end of its service life
The following are consumables:
- Motor
- Outdoor air filter
- Exhaust air filter
- Heat exchanger
■ Repair costs include technical fee, cost of parts, (and business trip charges), etc.
Manufactured by:
TOKYO BLDG. 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO, 100-8310 JAPAN
VL-250CZPVU-R-E
VL-250CZPVU-L-E
4
Fan speed icon
100%
[W]
106
[m
/h]
250
3
[L/s]
69
150
85
1
) [dB]
31
220-240 V / 50 Hz , 220 V / 60 Hz
A +
Heat recovery mode
3
2
1
70%
50%
30%
44
23
11
175
125
75
49
35
21
74
38
14
87
88
90
22
16
15>
26
If you hear strange noise, if no air is blown out or
if some other trouble occurs, turn off the power
and contact your dealer. Consult with your dealer
concerning the cost of inspection or repair work.
Eng-21
VL-350CZPVU-R-E
VL-350CZPVU-L-E
4
3
2
100%
70%
50%
155
71
37
320
224
160
89
62
44
150
74
38
85
87
88
35
26
19
32
1
30%
19
96
27
14
90
15>

Hide quick links:

Advertisement

Table of Contents
loading