Pelpro PPC90 Service Manual page 45

Hide thumbs Also See for PPC90:
Table of Contents

Advertisement

WATTS:
EXHAUST BLOWER
CONVECTION BLOWER
IGNITER
FEED MOTOR
AMPS:
EXHAUST BLOWER
CONVECTION BLOWER
IGNITER
FEED MOTOR
CONVECTION BLOWER VOLTS:
LOW TO HIGH (VAC)
EXHAUST BLOWER VOLT RANGE (76 TO 109+/- 2v, 0 trim):
POWER LEVEL 1
POWER LEVEL 2
POWER LEVEL 3
POWER LEVEL 4
POWER LEVEL 5
FEED MOTOR "ON" TIMES at 0 trim:
POWER LEVEL 1
POWER LEVEL 2
POWER LEVEL 3
POWER LEVEL 4
POWER LEVEL 5
BTU INPUT:
POWER LEVEL 1
POWER LEVEL 2
POWER LEVEL 3
POWER LEVEL 4
POWER LEVEL 5
CONVECTION BLOWER CFM:
HOPPER CAPACITY:
FREESTANDING
VACUUM: (COLD APPLIANCE, EXHAUST BLOWER VOLTS 115, FUEL IN HOPPER)
Note: Appliance was plugged into a 115V outlet. Voltages can vary depending on volts from the outlet.
45
PPC90 SPECIFICATIONS
8390-017A
56w
288w
300w
15w
.47A
2.4A
2.5A
125mA
62v to 115v
76v
80v
87v
95v
109v
0.9
1.5
1.9
2.3
2.7
11,055
47,378
250
90 lbs.
.14" TO .21"wc