Error codes will look
like this on the display
Fuel Feed Alarm. Most likely the appliance ran out of fuel or the flames are adjusted
Code #1
too low.
Exhaust Temperature is above or below the acceptable range. Exhaust probe has
Code #2
failed or the flames need to be adjusted.
Ambient Temperature is above or below the acceptable range.
Code #3
Ambient probe has failed.
Missed Ignition Alarm. Appliance has either ran out of fuel or the firepot needs to
Code #4
be cleaned. Also it is possible that the igniter has failed if the appliance is clean.
Digital Display Communication Alarm. Appliance lost power while the appliance
Code #5
was running or there was a bad connection from the display to the control board.
Board may need replaced.
Exhaust temperature over heat alarm. Appliance got too hot. Check the heat
Code #7
exchanger and exhaust system for obstructions. Make sure the flame height is
correct.