Electrical safety

The Premium spas are safe products, manufactured in com
60335-1, EN 60335-2-60, EN 12764 and tested during production
user safety.
to ensure
I
Installation must be carried out
sonnel
, in compliance with current national provisions.
It is the responsibility of the installer to select materials
based on their intended use, to carry out work properly,
to check the condition of the system that the unit will be
connected to and that it ensures safety of use also con-
cerning maintenance work and the possibility to examine
the system.
I
The Premium spas are class
must be permanently connected, without any intermediate con-
nections, to the electrical system and to the protection system
(earth system).
The electrical system of the building must be provided
with a 0.03A differential switch and with an efficient pro-
tection (earth) circuit.
Check for proper operation of the differential switch by
pressing the TEST button, which should trip.
Parts incorporating electrical components, except re-
mote control devices, must be located or fixed so that
they cannot fall into the spa.
Live components and equipment must be out of reach
of individuals in the spa.
I
For electrical connections, the installation of a multiple-pole sec-
tion switch is compulsory (
place that complies with safety regulations and, in any case, which
cannot be reached by those using the spa.
It is mandatory to comply with this instruction. Any other procedure is
prohibited.
I
The disconnection devices must be installed in the power supply
network according to the installation instructions.
I
The installation of electrical devices and equipment (sockets,
switches, etc.) near the spa must be in compliance with legal stan-
dards and regulations in the country where the spa is installed.
I
For the equipotential connection as required by specific national
standards, the installer must use the terminal provided (standard
EN 60335.2.60)in the electrical box (
the symbol
.
In particular, an equipotential condition must be established for all
metallic masses surrounding the spa, for example water and gas
pipes, metallic platforms, and so on.
by qualified and authorized per-
"I" appliances and therefore they
i
5-6-7). It must be positioned in a
i
5-6-7), and marked with
EN
33