Dedicated Menu Displays

The following displays in the LED panel will not have a corresponding speedometer needle
movement. These are in sequence after the  option.
The VSS calibration adjustment is from 75% to 125% of the current calibration value, or +/- 25%.
Calibration menu adjust (0 MPH): - LED: 
• If making a calibration percentage adjustment while using a VSS input (not OBDII), an
adjusted speed will reset the calibrated speed as the new 100% reference point.
• Tap the switch until "" is shown, then press and hold the switch to select it.
• Release the switch. The display will show either "" (make the speedometer faster) or ""
(make the speedometer slower).
• Tap the switch until the desired direction is shown, then press and hold the switch to select it.
• The display will show "". Tap the switch to change the percentage value
• Press and hold the switch to save it.
• Tap switch until "" and hold the switch. or turn the key off to exit setup.
Pulses menu display: - LED: 
• Shows the current pulse rate the ECD is set to drive the speedometer.
• This does not indicate the input VSS.
• When pressing and releasing the switch to get to , hold the switch until ""
• A number will appear,  = 8,000 PPM,  = 8,200 PPM

Input source menu

The ECD-200BT can read a regular electronic vehicle speed signal (VSS) from a dedicated
speed sensor or from a VSS output of an engine computer or transmission computer. It can also
read OBDII speed in 1996 and newer GM and Ford vehicles, and 2003 and newer Chrysler/Jeep
vehicles. It will not be able to read CAN speed from aftermarket ECMs like Holley or FAST, or non
US standard protocols.
Input menu display: - LED: 
• Press and hold the switch, then turn key on
• Tap switch until  is displayed. Hold switch until "" is displayed
•  = speed input signal will be from a VSS source
o Press and hold the switch until "" to save and exit to main menu
•  = speed input signal will be from a OBDII source
o When  is selected by holding the switch until "" appears two options appear
o  – saves and exits back to main menu
o  – a submenu of four ODBII channels to pick from, if the ECD conflicts with a scanner
▪ \  \  \ 
o Tap the switch to change the ID value
o Press and hold the switch to save until "" and exit to the main menu