NYCe 4000 Linear motion control sys-
tem
Drive power
DPx
Tab. 7-2: Drive power supply ratings
7.4 Motor connector ratings
The motor connector ratings for the NY4120/10 modules are specified in the
following table.
Motor type
Mx.0 and Mx.1
Tab. 7-3: Motor connector ratings
8 Standards
8.1 Used standards
The components of the system housing correspond to the following standard.
IEC61010-1:2010
●
measurement, control and laboratory use - Part 1: General requirements)
IEC61000-6-2:2005) (Electromagnetic compatibility (EMC) - Part 6-2: Generic
●
standards - Immunity for industrial environments)
IEC61000-6-4:2018 (Electromagnetic compatibility (EMC) - Part 6-4: Generic
●
standards - Emission standard for industrial environments)
8.2 CE marking
Declaration of Conformity
Fig. 8-1: CE logo
The system housing described in the present instructions, complies with the
requirements and the target of the following EU directive and with the following
harmonized European standards:
Low Voltage Directive 2014/35/EU
●
This product is a built-in unit which, owing to its installation characteristics, is
not able to comply with the regulations for complete apparatus, machines or
installations from the outset. For this reason, it may only be used for built-in
UN
DC +15 .. +75V
UN
DC 3x 0V .. 75V
(Safety
requirements
IN
Fan
12.0A
IN
Fan
0 .. 7Arms
for
electrical
R911383227_Edition 04 Bosch Rexroth AG
9/33
Standards
IN
Natural convection
6.0A
IN
Natural convection
0 .. 3Arms
equipment
for