HEAD OFFICE.FACTORY.R&D INSTITUDE
HITROL CO., LTD 141, Palhakgol-gil, Jori-eup
Paju-si, Gyeonggi-do, Korea
TEL. : (+82)-31-950-9700
FAX. : (+82)-31-943-5600
www.hitrol.com
INSTRUCTION MANUAL
CAPACITANCE TYPE LEVEL SWITCH
HITROL CO.,LTD.
HCC-95P-Ex Series
HCC-95P-Ex Series
IECEx KSCP 21.0019X
2021-04-27
Doc. no.: HCC95P-Ex(IECEx)_IM_Eng_Rev.0
Issue date: 2020. 10
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HCC-95P-Ex Series and is the answer not in the manual?

Questions and answers

Summary of Contents for HITROL HCC-95P-Ex Series

  • Page 1 HCC-95P-Ex Series HITROL CO., LTD. HEAD OFFICE.FACTORY.R&D INSTITUDE HITROL CO., LTD 141, Palhakgol-gil, Jori-eup Paju-si, Gyeonggi-do, Korea TEL. : (+82)-31-950-9700 FAX. : (+82)-31-943-5600 www.hitrol.com INSTRUCTION MANUAL CAPACITANCE TYPE LEVEL SWITCH HCC-95P-Ex Series IECEx KSCP 21.0019X 2021-04-27 Doc. no.: HCC95P-Ex(IECEx)_IM_Eng_Rev.0 Issue date: 2020. 10...
  • Page 2: Table Of Contents

    HCC-95P-Ex Series Table of Contents Overview · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ·3 APPENDIX E · · · · · · · · · · · · · HCC-95P Setting Guide APPENDIX H ·...
  • Page 3: Overview

    HCC-95P-Ex Series Overview HCC-95P Series can be installed on the top and side of the tank, and it is a Capacitance Type Level Switch device that converts, measures and senses the inherent dielectric constant of the measured object into a capacitance value, and outputs the water level.
  • Page 4: Specifications

    HCC-95P-Ex Series Specifications Model HCC-95P-Ex-XX HCC-95PH-Ex-XX HCC-95PW-Ex-X HCC-95PWH-Ex-X Probe Type Rod(Flat) Rope Mounting Flange & Screw Ambient Temperature -20°C ~ +60°C Process Temperature -40°C~+80℃ -40°C~+150℃ -40°C~+80℃ -40°C~+150℃ Process Pressure Vacuum~ 20kg/cm2(300#) AC 90~240V(0.03A), 50Hz/60Hz / DC 24V(0.06A) Power Source Contact Rating...
  • Page 5: Dimension And Technical Data

    HCC-95P-Ex Series Dimension and Technical Data The dimensions on the following pages are indicated in [mm]. [Housing] Material: Aluminum [Connection] Connection Type -Screw: PT 1” (Std.), NPT 1”, PF 1”, Others -Flange: ANSI, JIS, DIN -Tri-Clamp Material -304, 316L, Others High Temp.
  • Page 6 HCC-95P-Ex Series For Liquids For Solids Rod Probe Rod Probe Fully insulated Rod Probe Rope Probe w/ TEFLON Min. 1,000, Max. 10,000 Total length(L) 100~2,500 300~1,000 100~2,500 ≤2,500 ≤4,500 >4,500 Active Rod Length 100~1,000 150~500 100~1,000 (L-L1) Inactive Rod ~1,500...
  • Page 7: Installation

    HCC-95P-Ex Series When installing the sensor, avoid places with a lot of vibration or obstacles. Installation ■ The fluid flow is severe near the outlet, and it is easy to cause mechanical damage or ■ chattering, so installation near the outlet should be avoided.
  • Page 8: Cautions For Removal

    HCC-95P-Ex Series ■ Check the level and presence of liquid in the tank before removing it. Cautions ■ The product may be overheated so wear gloves to prevent burns. ■ If there is explosive gas in the atmosphere, do not open the cover.
  • Page 9: Precautions For Use

    HCC-95P-Ex Series ■ Users should use appropriate products by judging the explosion-proof area of the related Precautions products. for Use ■ Do not bend the sensor, which is the measurement part, or cut or expand it arbitrarily. ■ Apply power after installation is completed and cover of product is fastened.
  • Page 10: Cautions For Inserted External Wire

    HCC-95P-Ex Series ■ Use the cable gland connection or metal pipe line lead-in on the wire inlet, and use Cautions a product with an equivalent ex-proof certificate to connect it using the external line lead-in method. Inserted ■ For an unused external line inlet, use a closing plug with an equivalent ex-proof certificate.
  • Page 11: Label

    HCC-95P-Ex Series Label ■ Label The label is attached on the housing to state the model, serial number, working temperature, working pressure, and output. The serial number is a unique manufacturing number. ■ IECEx Certification standard IEC 60079-0 : 2017 Edition : 7.0 Explosive atmospheres –...
  • Page 12: User Training

    You can request A/S from our website or by contacting our headquarters. Headquarters, Factory, and Research Center (Contacts) ■ Address: Hitrol, 141, Palhakgol-gil, Jori-eup, Paju-si, Gyeonggi-do, Republic of Korea (Palhakgol-gil 98) HITROL CO., LTD. 141, Palhakgol-gil, Jori-eup, Paju-si, Gyeonggi-do, Korea TEL.: 031-950-9700 (Headquarters and A/S)
  • Page 13 APPENDIX E HCC-95P 조정방법 설명서 Capacitance Type Level Switch Doc. no. : Rev1.0...
  • Page 14 1. M-95P 구성 및 기능 구성 기능 ■ Autoset SET. ○ Tank내 정전용량 자동 측정 및 기준 ■ 정전용량 측정 감도 범위 설정 RANGE ○ 감도 설정 범위 : 10pF ~ 150pF ○ 감도 설정 방법 : BCD Dip Switch ■...
  • Page 15 2. M-95P 세팅 및 조정 방법 ■ 초기화 세팅 방법 □ Tank 설치 후 빠른 응답성을 위하여 초기화 상태로 세팅합니다. ■ Tuning 세팅 방법 1 □ “Autoset 설정 후 감도 조정”에 따른 세팅 방법입니다. 기능 방법 ■ “SET.” Tact Switch를 1초간 누르면 PWR LED가 점.소등 됩니다. ■...
  • Page 16 ■ Tuning 세팅 방법 2 □ “감도 조정 후 Autoset”에 따른 세팅 방법입니다. 기능 방법 ■ “SEN.” VR로 측정 매질의 감도 변화값을 설정합니다. SEN. ■ LED가 켜져 있을 수도 있습니다. ■ “감도 조정 방법” 참조 바랍니다. ■ “SET.” Tact Switch를 1초간 누르면 PWR LED가 점.소등 됩니다. ■...
  • Page 17 ■ 감도 조정 방법 □ Dry Contact 환경 설치 시 측정 감도를 조정할 수 있습니다. 기능 방법 ■ 측정 매질의 미접촉 상태입니다. Dry Contact 환경 ■ “SET.” Tact Switch를 누른 후 조정 가능합니다. SET. ■ 감도 설정 및 조정 후 “SET.” Tact Switch를 누를 수 있습니다. ■...
  • Page 18 □ Wet Contact 환경 설치 시 측정 감도를 조정할 수 있습니다. 기능 방법 ■ 측정 매질의 접촉 상태입니다. Wet Contact 환경 ■ “SET.” Tact Switch를 누른 후 조정 가능합니다. SET. ■ 감도 설정 및 조정 후 “SET.” Tact Switch를 누를 수 있습니다. ■...
  • Page 19 □ 측정 감도 설정 및 세밀 조정 영역.
  • Page 20 ■ Relay 동작 시간 조정 방법 □ 측정물 감지 후 Relay 동작 시간을 조정할 수 있습니다. 기능 방법 ■ Relay Delay Time 시간 조정 범위 : 0.5s, 1s ~ 10s @ Adjustment 0.1s ■ □ 측정물 미감지 후 Relay 복귀 시간을 조정할 수 있습니다. 기능...
  • Page 21 ■ Fail Safe Mode 조정 방법 □ Relay Contact N.C 접점 상태를 조정할 수 있습니다. 기능 방법 ■ Relay Contact Out 기본 상태입니다. ■ 측정물 감지 후 Relay Contact이 N.C → N.O로 접점이 변경됩니다. ■ LED 동작 상태. □ Relay Contact N.O 접점 상태를 조정할 수 있습니다. 기능...
  • Page 22 3. M-95P UART Monitoring ■ Monitoring 방법 □ PC 및 Smartphone 을 이용하여 조정된 설정값 상태만 확인할 수 있습니다. □ PC 및 Smartphone 을 이용한 사용방법은 동일합니다. (Password : 1975) □ 실행 화면 구성 : 센서 측정 상태, 감도 설정값, Relay 설정 상태 등 ■...
  • Page 23 ■ Smartphone 를 이용한 Monitoring 방법 □ 구성품 : Smartphone(Android OS), OTG, USB 연장 케이블(일반 USB to Micro USB B), UART ADAPTOR. □ App : 당사 “Serial USB Terminal Install & Setting Guide” 참조.
  • Page 24 APPENDIX H Serial USB Terminal Serial USB Terminal Install & Setting Guide Application : Level Switch / Level Transmitter Doc. no. : Rev0.0 Issued Date : 2020.04.29...
  • Page 25 ■ Installing Serial USB Terminal App □ Search and Install a App that "Serial USB terminal" in the App Store. ■ Serial USB Terminal Setting □ Run The Serial USB Terminal Icon □ Four types of environments must be set up for normal operation of Serial USB Terminal. ▶...
  • Page 26 ■ Serial – Baud rate Setting □ Baud rate : 19200 -> 9600 [Complete] [Select Baud rate] [Setting] [Default] ■ Terminal - Show connection message / Show timestamps Setting □ Show connection message : ON -> OFF □ Show timestamps : ON -> OFF □...
  • Page 27 ■ Receive – Newline Setting □ Newline : CR+LF (Carriage Return + Line Feed) Check [Default] ■ Send - Newline Setting □ Newline : Auto(same as Receive) -> CR [Select Newline] [Default] [Setting] [Complete] Doc. no. : Rev0.0 Issued Date : 2020.04.29...
  • Page 28 ■ Send - Character delay Setting □ Character delay : 0ms -> 5ms [Complete] [Setting] [Default] [Select Character delay] ■ Send – Local echo / Clear input on send Setting □ Local echo : ON -> OFF □ Clear input on send : OFF -> ON [Complete] [Complete] [Select Local echo]...