Important! The fitting must be installed,
flushed and tested after the valid norms.
The hot and cold supplies must be of equal
pressures.
Technical Data
Operating pressure:
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temperature: 65° C
Centre distance:
Connections G ½:
Rate of flow by 0,3 MPa:
Back flow and vacuum breaker
Hansgrohe mixers can be used together with hy-
draulically and thermically controlled continuous
flow heaters if the flow pressure is at least 0,15
MPa.
Important!
The non return valves must be checked regularly
according to DIN EN 1717 in accordance with
national or regional regulations (at least once a
year).

Operation

Hot surface!
English
max. 1 MPa
1,6 MPa
max. 80° C
170 ± 44 mm
cold right
hot left
approx. 18 l/min
Spare parts (see page 3)
1
handle
2
screw cover for cold / hot water 97987000
3
sleeve
4
aerator cpl. M24x1
5
shut off unit,
6
non return valve
7
selector
8
noise reduction
9
sliding gear lever
10
cover cap set
11
shower base
12
shower holder
13
hose 1,25 m
14
filter packing
15
hexagon socket screw M10x35 (set) 97670000
16
supply pipe (set)
XXX = Colors
000 chrome plated
820 brushed nickel
830 polished nickel
16597XXX
97993XXX
98575XXX
94009000
94074000
98591000
96429000
98594XXX
98593XXX
98590XXX
16320XXX
28112XXX
94246000
97226000
7