Pace VF 100 SMT Operation Manual

Desoldering system

Advertisement

Quick Links

VF 100 SMT Desoldering System Operations Manual (P/N 5050-0499)
1. Packing Contents (P/N 8007-0356-P1 or 8007-0357-P1)
a. VF 100 System (1 each)
b. Hand-piece (1 each)
c. Power Cord (1 each)
d. Standard Tip (1 each)
e. Filter Cartridge (1 each)
f. Secondary Filter (1 each)
g. Filter Chamber (1 each)

2. Specification

Station
Voltage
8007-0356-P1
8007-0357-P1
Power
Consumption
Pump Type
Dimensions
Weight
Power Cord
Length
120 VAC
230 VAC
100 W max
Diaphragm (2
sets)
227 mm (9") H x
130 mm (5.1")
W x 118 mm
(4.7") D
3.5 KG (7.7
Pounds)
1.2 m (48")
Hand-piece
Heater Type 24 V, Ceramic,
80 W max, Zero
point switching
Resistance
100 MΩ at 400°
C (750° F)
Maximum
500 mm Hg
Vacuum
Hot Air Flow 3 lpm
Temp
200-400° C (390-
Range
750° F)
Dimensions
120 mm (4.75")
H x 195 mm
(7.7") W x 28
mm (1.1") D
Weight
120 g (4.1 oz)
without cord

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VF 100 SMT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pace VF 100 SMT

  • Page 1 VF 100 SMT Desoldering System Operations Manual (P/N 5050-0499) 1. Packing Contents (P/N 8007-0356-P1 or 8007-0357-P1) a. VF 100 System (1 each) b. Hand-piece (1 each) c. Power Cord (1 each) d. Standard Tip (1 each) e. Filter Cartridge (1 each) f.
  • Page 2 VF 100 Operations Manual, Rev A Figure 1: Station VF 100 Seal Vacuum Port Figure 2: Hand-piece 3. Safety Information a. Do not contact the Heater or its peripheral parts during operation. b. Once turned off, let the unit cool completely before contacting. c.
  • Page 3 VF 100 Operations Manual, Rev A 4. Features As shown in the left illustration, the hot air blowing from the circumference of the tip enables effective pre-heating of the work. 5. Set-Up a. Connect Power cord, Plug & Tube of Iron to Main body.
  • Page 4 VF 100 Operations Manual, Rev A f. When the reverse side of PCB is preheated with the optional “HS- 100”, desoldering will be faster and the finish will be better. g. The joint use of “PH-100” is recommended to handle higher mass PCBs and when using the slim tip.
  • Page 5 VF 100 Operations Manual, Rev A access restricted areas. For best performance, the HS 100 should be used when the slim tip is used. Because the slim tip is long and thin, heat transfer is reduced when compared to the standard tip b.
  • Page 6 R1/8, and then supply 0.5-1.0 I/min. N2 from a Nitrogen farm, such as PACE’s NF 500 (P/N 8110-0001) and NF 1000 (P/N 8110-0002) is recommended. 14. Muffler A muffler has been fitted to the back of the VF 100 to reduce the noise level.
  • Page 7 VF 100 Operations Manual, Rev A Part Name Part Number Remarks Heater 6700-0001-P1 For Iron Filter Cartridge 6700-0002-P1 For Iron One Pack contains Filter 6700-0003-P1 For Iron 5 pieces One Pack contains Secondary Filter 6700-0004-P1 For Iron 5 pieces Standard Tip 6700-0005-P1 For Iron Slim Tip...
  • Page 8 The system is in conformity with the Low Voltage Directive and EMC Directive 73/23 EEC as last amended by EEC Directive 93/68/EEC. 19. Service Please contact PACE or your local distributor for service and repair. www.paceworldwide.com PACE USA PACE Europe...

Table of Contents