Boot Device Options, Scsiselect - Intel R440LX Product Manual

Server motherboard
Table of Contents

Advertisement

and termination on the adapter cannot be disabled. On a 16-bit adapter,
termination is enabled for both the low byte (bits 0-7) and the high byte
(bits 8-15). If there is no 8-bit adapter at the end of the bus, you must
disable termination by using the option in the SCSISelect Configuration
menu. This is the termination model:
Host adapter location
Installed at end of bus
Installed at end of bus
Not at end of bus*
Not at end of bus*
* In this system, the host adapter on the motherboard is always at one end of the bus.
Boot Device Options, SCSI Select
Feature
Boot Target ID
Boot LUN
Number
Boot Target ID—The default boot device is the device at SCSI ID 0 with
logical unit number (LUN) 0. To specify a different boot device, choose a
different SCSI ID (0 through 7 on 8-bit adapters, 0 through 15 on 16-bit
adapters).
Boot LUN Number—If the boot device has multiple logical units, you must
also specify the boot logical unit number (LUN). This can be 0 through 7
(on 8-bit or 16-bi5t adapters). Multiple LUN support can be disabled in the
SCSISelect Advanced Configuration menu.
R440LX Server Motherboard Product Guide
SCSI devices
connected to bus
only 8-bit, or
only 16-bit
both 8-bit and 16-bit
only 16-bit
both 8-bit and 16-bit
Option
Comment
0−15
The default boot device is at SCSI ID 0 with logical unit
number (LUN) 0. To specify a different boot device,
choose a different SCSI ID (0 through 7 on 8-bit
adapters, 0 through 15 on 16-bit adapters).
0−7
The logical unit number (LUN) can be 0 through 7 (on
8-bit or 16-bit adapters).
If you disable Multiple LUN Support in the Advanced
Configuration menu, specifying a number here has no
effect.
Host Adapter SCSI Termination
choice
Low ON/High ON (default)
Low ON/High ON (same as default)
Note: Last device must be
16-bit and terminated.
Low OFF/High OFF
Low OFF/High On
73