A. Vent Components Diagrams (continued)
15 in.
(381 mm)
Figure 12.5 DVP Vent Components
Fire Risk.
• When using SLP-HRC-SS termination cap
on top vented fireplaces, a one foot minimum
vertical vent section is required before installing
first elbow.
• When using DVP-TB1 termination cap on top vented
fireplaces, a three foot minimum vertical vent section is
required before installing first elbow.
Figure 12.6 SLP Vent Components
DECORATIVE TERMINATIONS/SHROUDS
Only use listed decorative termination caps/shrouds with Hearth & Home Technologies approved venting systems.
This applies to both DVP and SLP venting systems.
Decorative Terminations Caps/Shrouds
DTO134
DTO146
DTS134
DTS146
62
8-1/8 in.
13 in.
(206 mm)
(330 mm)
HORIZONTAL TERMINATION CAP
WARNING
SL-2DVP
SLP90
ASSEMBLY
HORIZONTAL TERMINATION CAP
LDS33
LDS46
LDS-BV
Majestic • MERC32IN, MERC32IL Installation Manual • 2401-980 Rev. L • 1/21
Effective Length
5-1/2 in.
5-3/4 to 8-3/8 in.
140 mm
146 to 213 mm
DVP-HRC-SS
DVP-HRC-ZC-SS
15 in.
(381 mm)
DVP-TB1
DVP-TB1
DVP-TB1
8-3/8 in.
213 mm
87°
10-1/2 in.
267 mm
10-7/8 in.
276 mm
8-1/8 in.
(206 mm)
SLP-HRC-SS
Horizontal Termination Cap
13 in.
(330 mm)