UNMAK UKY/W User Manual

Hot water boiler

Advertisement

Quick Links

Manuel Feeding,
Wood Fired Boiler
User Manual
ÜNLÜSOY
Yapı Malzemeleri Sanayi ve Ticaret Ltd. Şti.
Pancar Organize Sanayi Bölgesi, 2. Etap No:2, Torbalı – İZMİR
Tel: +90 444 35 32, Fax: +90 232 469 2412
www.unmak.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UKY/W and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for UNMAK UKY/W

  • Page 1 Manuel Feeding, Wood Fired Boiler User Manual ÜNLÜSOY Yapı Malzemeleri Sanayi ve Ticaret Ltd. Şti. Pancar Organize Sanayi Bölgesi, 2. Etap No:2, Torbalı – İZMİR Tel: +90 444 35 32, Fax: +90 232 469 2412 www.unmak.com...
  • Page 2: Table Of Contents

    Manuel Fuel Feeding, ÜKY/W Hot Water Boiler User Manual P a g e INDEX INDEX ..............................1 INTRODUCTION ........................... 2 SHIPPING AND TRANSPORTATION ...................... 2 SELECTION OF INSTALLATION PLACE ....................3 SAFETY PRECAUTIONS ......................... 5 ELECTRICAL INSTALLATION INSTRUCTIONS..................6 BOILER FEATURES ..........................7 RULES FOR HEATING INSTALLATION ....................
  • Page 3: Introduction

    UNMAK boilers convert the chemical energy of the fuel into heat energy by burning and load it onto the water which is the heating fluid. Excessive fuel overcharging to the combustion chamber will cause energy loss and will take longer to burn.
  • Page 4: Selection Of Installation Place

    Manuel Fuel Feeding, ÜKY/W Hot Water Boiler User Manual P a g e In order to prevent damage to the boiler's outer plates and the boiler during transportation; It is also convenient to remove the large grates from the forklift stands or the transport ring on the boiler. If the connection ropes are to be passed under the boiler when lifting by crane, preventive action should be taken to prevent the top of the boiler from being crushed by the ropes.
  • Page 5 Manuel Fuel Feeding, ÜKY/W Hot Water Boiler User Manual P a g e The boiler room must have at least 1 piece 6 kg dry powder dry fire extinguisher and at least 1 fire cabinet in large boiler rooms. If natural gas or liquid fuel boilers are also used in the same boiler room, a tear surface must be designed.
  • Page 6: Safety Precautions

    Manuel Fuel Feeding, ÜKY/W Hot Water Boiler User Manual P a g e SAFETY PRECAUTIONS The boiler must be connected to a chimney in accordance with the specifications specified in the operating instructions and the relevant regulations. The chimney must provide the draft value required by the connected boiler.
  • Page 7: Electrical Installation Instructions

    Manuel Fuel Feeding, ÜKY/W Hot Water Boiler User Manual P a g e exceeded. In order to minimize the water missing in the installation, the water level should be checked regularly and the leaks in the system should be removed. Because excessive water additions to the system will cause lime accumulation on the water side of the boiler and this will cause regional overheating and this will damage the boiler.
  • Page 8: Boiler Features

    Manuel Fuel Feeding, ÜKY/W Hot Water Boiler User Manual P a g e BOILER FEATURES MODEL: ÜKY/W Fuel Type Log Wood Power (Coal) 23-25 32-35 42-45 57-60 kcal/h 19,780 - 27,250 - 36,120 - 49,020 - 21,500 30,100 38,700 51,600 Power (Wood) 20 - 22 27 - 30...
  • Page 9: Rules For Heating Installation

    Manuel Fuel Feeding, ÜKY/W Hot Water Boiler User Manual P a g e RULES FOR HEATING INSTALLATION Pay attention to the figure on the right while positioning the pump. When assembled, the junction box with the electrical terminals of the pump should not come down. The rotor part of the pump should not be pointing down.
  • Page 10 Manuel Fuel Feeding, ÜKY/W Hot Water Boiler User Manual P a g e temperature in the water. Expansion tanks also fulfill the safety of the system, that is, the pressure does not rise, and the necessary water support functions for the system. Open expansion tanks: At the top of the system, the roof is put on the level difference and works open to the atmosphere.
  • Page 11 Adding fresh water to the installation should only be carried out when the installation is cold. Warning of corrosion in installation: UNMAK boilers are extremely resistant to corrosion. However, all iron-based components in the heating installation (including installation pipes and radiators) must be protected against corrosion.
  • Page 12: Usage And Installation Of Draft Regulator

    Manuel Fuel Feeding, ÜKY/W Hot Water Boiler User Manual P a g e | 11 first place to start corrosion. Therefore, when a new boiler is connected to the old heating system, in addition to the measures to be taken for new systems, the following issues should be considered: 1.
  • Page 13: Start-Up

    Manuel Fuel Feeding, ÜKY/W Hot Water Boiler User Manual P a g e | 12 START-UP The following steps should be followed for the initial start of the boiler:  Check for any visible glitches in the installation. If there is an error, please refer to the "Information on Usage Errors"...
  • Page 14 Never use a hollow brick on the chimney walls. The most ideal is the creation of fire bricks. UNMAK boilers must be connected to an independent chimney that can provide the minimum desired minimum traction. Minimum traction is usually min. It should be measured with a manometer in 20 Pa.
  • Page 15: Maintenance And Boiler Cleaning

    Manuel Fuel Feeding, ÜKY/W Hot Water Boiler User Manual P a g e | 14 MAINTENANCE AND BOILER CLEANING For your system to work efficiently, regular maintenance is required by specialist teams according to the manufacturer's instructions. Regular checks: • The water level should always be checked. The hydrometer (water level indicator) should be marked after the first filling of the system.
  • Page 16: Information On Usage Errors

    Manuel Fuel Feeding, ÜKY/W Hot Water Boiler User Manual P a g e | 15 INFORMATION ON USAGE ERRORS PROBLEM CAUSE SOLUTION • Boiler heat transfer surfaces may be • Clean with a spatula. (the boiler coated with soot and soot should not burn) •...
  • Page 17 Do not open the boiler flaps at power cuts, do not water boiler in the boiler. ÜNLÜSOY YAPI MALZEMELERİ SANAYİ ve TİCARET LİMİTED ŞRKETİ Address: Pancar Organize Sanayi Bölgesi, 2. Etap No:2, Torbalı – İZMİR/TURKEY Tel: +90 444 35 32, Fax: +90232 469 2412 www.unmak.com...