Distribution Box "Ds300-St; Protection Fuses - CBE PC380-ST User Manual

Hide thumbs Also See for PC380-ST:
Table of Contents

Advertisement

Available languages

Available languages

EN

DISTRIBUTION BOX "DS300-ST"

PROTECTION FUSES

5A fuse to give power to the awning light.
1)
10A fuse to give power to the water pump.
2)
10A fuse to give power to the heating/boiler.
3)
4)
20A fuse to give power to the lights group "A".
5)
20A fuse to give power to the lights group "B".
6)
30A fuse to give power to 12V AES or 3-way
function fridge. The 3-way function fridge
switches automatically off when the engine is
off.
7)
20A fuse for the auxiliary power supply (solar
regulator), which is directly connected to the
leisure (B2) battery.
24
2
4
B
1
3
5
18
1 2
13
15
14
8
1
1 2 3 4
16
9
19
-B2
20
6
8
10
AUX
7
9
17
11
1 A
6
12
1 B
6
+B2
+B1
21
22
25A fuse for the electrical step power supply,
8)
connected directly to the leisure (B2) battery.
9)
3A fuse for the gas power supply (fridge,
kitchen, boiler valve, etc.), connected directly
to the leisure (B2) battery.
10) 3A fuse for OUT D+ simulated exit protection.
11) AES fridge connection; It is a bridge, which
excludes the 3 way function fridge and is used
to connect the AES fridge directly to the B2.
12)
Simulated output D+ alternator to control the
electrical step, AES refrigerator, electrical
draining valve, coming-back of the electrical
antenna.
etc.)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents