Shinko DSW-100-TH Installation Instructions Manual

Indoor temperature/humidity sensor

Advertisement

Quick Links

Installation Instruction Manual
Preface
Thank you for purchasing our DSW-100-TH, Indoor Temperature/Humidity Sensor.
This manual contains instructions for installation and handling of the DSW-100-TH. To ensure safe and correct
use, thoroughly read and understand this manual before using this sensor. To prevent accidents arising from
the misuse of this sensor, please ensure the operator receives this manual.
Notes
• This sensor should be used in accordance with the specifications described in the manual. If it is not used
according to the specifications, it may malfunction or cause a fire.
• Be sure to follow all of the warnings, cautions and notices. If they are not observed, serious injury or
malfunction may occur.
• The contents of this instruction manual are subject to change without notice.
• Care has been taken to assure that the contents of this instruction manual are correct, but if there are any
doubts, mistakes or questions, please inform our sales department.
• Any unauthorized transfer or copying of this document, in part or in whole, is prohibited.
• Shinko Technos Co., Ltd. is not liable for any damage or secondary damage(s) incurred as a result of using
this product, including any indirect damage.
Safety Precautions
The safety precautions are classified into 2 categories: "Warning" and "Caution".
Depending on the circumstances, procedures indicated by
so be sure to follow the directions for usage.
Warning
Procedures which may lead to dangerous conditions and cause death or serious injury, if not carried
out properly.
Caution
Procedures which may lead to dangerous conditions and cause superficial to medium injury or physical
damage or may degrade or damage the product, if not carried out properly.
Warning
• To prevent an electrical shock or fire, only Shinko or other qualified service personnel may handle the
inner assembly.
• To prevent an electrical shock, fire or damage to the instrument, parts replacement may only be
undertaken by Shinko or other qualified service personnel.
SAFETY PRECAUTIONS
• To ensure safe and correct use, thoroughly read and understand this manual before using this
instrument.
• This instrument is intended to be used for general equipment. Verify correct usage after purpose-of-use
consultation with our agency or main office.
(Never use this instrument for medical purposes with which human lives are involved.)
• External protection devices must be installed, as malfunction of this product could result in serious
damage to the system or injury to personnel. Proper periodic maintenance is also required.
• This instrument must be used under the conditions and environment described in this manual.
Shinko Technos Co., Ltd. does not accept liability for any injury, loss of life or damage occurring due to
the instrument being used under conditions not otherwise stated in this manual.
Caution with Respect to Export Trade Control Ordinance
To avoid this instrument from being used as a component in, or as being utilized in the manufacture of
weapons of mass destruction (i.e. military applications, military equipment, etc.), please investigate the
end users and the final use of this instrument.
In the case of resale, ensure that this instrument is not illegally exported.
Indoor Temperature/Humidity Sensor
(Be sure to read these precautions before using our products.)
1
和文は裏面をご覧ください。
DSW-100-TH
Caution may result in serious consequences,
No.DSW13JE4 2018.07

Advertisement

loading
Need help?

Need help?

Do you have a question about the DSW-100-TH and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Shinko DSW-100-TH

  • Page 1 • Any unauthorized transfer or copying of this document, in part or in whole, is prohibited. • Shinko Technos Co., Ltd. is not liable for any damage or secondary damage(s) incurred as a result of using this product, including any indirect damage.
  • Page 2 1. Model 1.1 Model Model Measurement Range Output Temperature: 100 (Pt100) 3-wire type DSW-100-TRH Humidity: 4 to 20 mA DC 2-wire type Temperature: 100 (Pt100) 3-wire type DSW-100-TRH W4 Humidity: 4 to 20 mA DC 4-wire type Temperature: 100 (Pt100) 3-wire type DSW-100-TRHV W4 Humidity: 0 to 1V DC...
  • Page 3: Fixing The Mounting Plate

    (3) Mounting Main Unit Screw 4 places as indicated by the dotted lines, and fix the sensor main unit to the Mounting Plate. For screws, use M3 screw (4 pieces) provided. (1) Fixing the Mounting Plate Screw either (A) or (B), and fix the Mounting Plate to the outlet box, via outlet box cover located inside the wall.
  • Page 4: Specifications

    5. Specifications Measurement Range Temperature: 0 to 50 Humidity: 5 to 90 %RH Output Temperature Humidity DSW-100 -TRH, -TRH W4 100 (Pt100), 3-wire type 4 to 20 mA DC (Linear conversion 4 to 20 mA DC (Linear conversion corresponding to 0 to100 %RH) 2-wire or 4-wire type (Selectable) DSW-100 corresponding to 0 to 50 )
  • Page 5 For the English manual, see the reverse. 設置用取扱説明書 DSW-100-TH 室内形温湿度センサ No.DSW13JE4 2018.07 はじめに このたびは,室内形温湿度センサ[DSW-100-TH](以下,本器)をお買い上げ頂きまして,まことにありが とうございました。 この取扱説明書(以下,本書)は,本器の設置方法および取扱いについて説明したものです。 本書をよくお読み頂き,十分理解されてからご使用くださいますようお願い致します。 また,誤った取扱いなどによる事故防止の為,本書は最終的に本器をお使いになる方のお手元に,確実に 届けられるようお取り計らいください。 ご注意 ・本器は,記載された仕様範囲内で使用してください。 仕様範囲外で使用した場合,火災または本器の故障の原因になります。 ・本書に記載されている警告事項,注意事項を必ず守ってください。 これらの警告事項,注意事項を守らなかった場合,重大な傷害や事故につながる恐れがあります。 ・本書の記載内容は,将来予告なしに変更することがあります。 ・本書の内容に関しては万全を期していますが,万一ご不審な点や誤り等お気づきのことがありましたら, お手数ですが裏面記載の弊社営業所までご連絡ください。 ・本書の記載内容の一部または全部を無断で転載,複製することは禁止されています。 ・本器を運用した結果の影響による損害,弊社において予測不可能な本器の欠陥による損害,その他す べての間接的損害について,いっさい責任を負いかねますのでご了承ください。 安全上のご注意 ご 使 用 前 に 必 ず お 読...
  • Page 6 神奈川 TEL: (045)361-8270 FAX: (045)361-8271 TEL: (072)727-4571 FAX: (072)727-2993 北 陸 TEL: (076)479-2410 FAX: (076)479-2411 [URL] http://www.shinko-technos.co.jp 広 島 TEL: (082)231-7060 FAX: (082)234-4334 大 阪 営 業 所 〒562-0035 大阪府箕面市船場東 2 丁目 5 番 1 号 福 岡 TEL: (0942)77-0403 FAX: (0942)77-3446...
  • Page 7 ③ 本体の取り付け 点線の矢印の 4 箇所をねじ留めし, ア テ板に本体を取り付けてください。 ねじは,付属の M3 ねじ(4 本)を使用 してください。 ① アテ板の取り付け (A)または(B)のいずれかをねじ留めし,壁 内のボックスカバーとアテ板を固定して ください。 ねじは,付属の M4 ねじ(2 本)とスプリン グワッシャを使用してください。 ② 配 線 ④ 本体カバーの取り付け 本体のリード線と壁側の線を結線 を行なってください。 本体カバーの突起(2 箇所)を,本体上部にあるカバー 取り付け穴(2 箇所)に差し込み装着してください。 3. 結 線 DSW-100-TRH DSW-100-TRH W4, DSW-100-TAH DSW-100-TAH W4, DSW-100-TRHV W4 DSW-100-TAHV W4...
  • Page 8 5. 仕 様 測定範囲 温度: 0~50 ,湿度: 5~90 %RH 出 力 温 度 湿 度 (Pt100) 3 線式 DSW-100-TRH, -TRH W4 4~20 mA DC 4~20 mA DC (0~100 %RH に対してリニア) に対してリニア) (0~50 2 線式または 4 線式を選択 DSW-100-TAH, -TAH W4 2 線式または 4 線式を選択 最大許容負荷: 500 以下...

This manual is also suitable for:

Dsw-100-trhDsw-100-trh w4Dsw-100-trhv w4Dsw-100-tahDsw-100-tah w4Dsw-100-tahv w4