14 through 20-Inch Design V150 and V300
Valve Sizes and End Connection Styles
Design V150: 14, 16, and 20-inch sizes with Class
150 raised-face flanges as shown in table 3
Design V300: 14 and 16-inch sizes with Class 300
raised-face flanges as shown in table 3
Maximum Inlet Pressures
Consistent with the pressure-temperature ratings in
table 3, but do not exceed the material temperature
capabilities or the pressure drop limitations shown
(2)
in the bulletin
. For CG8M (317 stainless steel)
valves, the pressure-temperature tables are shown
(2)
in the bulletin
Maximum Shutoff Pressure/Temperature Ratings
Composition (TCM, TCM III, and TCM IIIC) and
HD (Heavy Duty) Metal Ball Seals: Refer to the
(2)
bulletin
. For information on pressure classes,
contact your Fisher Controls sales office or sales
representative
Shutoff Classification
Composition Ball Seal (Forward Flow): Class VI
per ANSI/FCI 70-2-1991 and per IEC 534-4,
Amendment 1 (1986)
HD (Heavy Duty) Metal Ball Seal (Bidirectional
Flow): 0.01% of valve capacity at full travel; Class
IV per ANSI/FCI 70-2-1991 and per IEC 534-4,
Amendment 1 (1986)
Flow Ring Construction (Bidirectional Flow):
5% of valve capacity at full travel
Material Temperature Capabilities
Composition Seals: –50 to 450 F (–46 to 232 C)
HD Metal Seals: –50 to 550 F (–46 to 288 C)
Flow Ring with PTFE Packing: –50 to 450 F (–46
to 232 C)
Flow Ring with Graphite Ribbon Packing: –325
to 1000 F (–198 to 538 C)
1. The pressure or temperature limits in this manual and any applicable code limitations, should not be exceeded.
2. Refer to the appropriate Bulletin 51.3:V150 or 51.3:V300 for additional information.
VALVE SIZE
Inch
Inch
14
16
16
(1)
20
1. 20-Inch size available only for V150, not for V300 valves.
2
Table 1. Specifications
(1)
(1)
Table 2. Valve Sizes, Drive Shaft Diameters, and Valve Assembly Weights
mm
mm
Inch
Inch
350
1-3/4
2-1/8
400
400
2-1/8 x 2
(1)
500
2-1/2
PEEK/PTFE Bearings: –50 to 500 F (–46 to
260 C)
Flow Characteristic
Approximately equal percentage
Standard Flow Direction
Forward (into the convex sealing face of the
V-notch ball)
Actuator Mounting
Right-hand, or
upstream end of the valve
(1)
Maximum Ball Rotation
90 degrees
Valve/Actuator Action
With diaphragm or piston rotary actuator, field-re-
versible between push-down-to-close (extending
actuator rod closes valve) and push-down-to-open
(extending actuator rod opens valve)
Face-to-Face Dimensions
Design V150
14 and 16-Inch Valves: Consistent with ASME
B16.10 short
20-Inch Valves: 20 inches (508 mm)
Design V300
14-Inch Valves: 15 inches (381 mm)
16-Inch Valves: 16 inches (406 mm)
Drive Shaft Diameters and Valve Assembly
Weights
See table 2
14, 16, and 20-Inch Valves: Standard valve
construction is with right-hand mounting. Left-hand
mounting (optional) is available upon request.
DRIVE SHAFT
DIAMETER
mm
mm
44.5
54.0
54.0 x 50.8
63.5
left-hand as viewed from the
VALVE
ASSEMBLY WEIGHT
lb
kg
V150
V300
V150
545
825
206
735
735
1125
1125
333
333
1155
- - -
524
V300
374
510
510
- - -

Hide quick links: