Direct Supply Attendant A5LC-1 Owner's Manual

Direct Supply Attendant A5LC-1 Owner's Manual

5-liter oxygen concentrator

Advertisement

Attendant
®
5-LITER OXYGEN
CONCENTRATOR
A5LC-1
Owner's Manual
Please keep and refer to this Owner's Manual.
Thank you for purchasing an Attendant
Oxygen Concentrator from Direct Supply
®
Equipment & Furnishings
. Please read this entire guide carefully and keep it for future
®
reference. This guide will provide you with instructions, warnings, warranty information
and other important information about your oxygen concentrator. Share this information
with your housekeeping, nursing and maintenance staff to help ensure the oxygen
concentrator is cared for properly.
1-800-634-7328 DirectSupply.com

Advertisement

Table of Contents
loading

Summary of Contents for Direct Supply Attendant A5LC-1

  • Page 1 CONCENTRATOR A5LC-1 Owner’s Manual Please keep and refer to this Owner’s Manual. Thank you for purchasing an Attendant Oxygen Concentrator from Direct Supply ® Equipment & Furnishings . Please read this entire guide carefully and keep it for future ®...
  • Page 2: Table Of Contents

    • : Attention! Read the instructions. CONCENTRATOR or DEVICE: Your Attendant 5 Liter Oxygen Concentrator. ® YOU and YOUR: The facility, community or other entity that has purchased the product. WE, US, and OUR: Direct Supply Manufacturing, Inc.
  • Page 3: Intended Use For The A5Lc-1

    Intended Use for the A5LC-1 The A5LC-1 oxygen concentrator is intended for use by a resident in the home, hospital, or hospital-like facility as an oxygen supplement device. The concentrator is an electronically operated device that separates oxygen from ambient air, providing high concentration of oxygen directly to the resident through a nasal cannula or other method.
  • Page 4: Warnings & Cautions

    Do not use or assemble if you do not understand the contents of this manual – contact Direct Supply supply for assistance. Damage, injury or even death may result from improper use of this product or not following the directions and warnings. This product is intended for use in normal, indoor conditions.
  • Page 5 • WARNING: Spontaneous and violent ignition may occur if oil, grease or greasy substances come in contact with oxygen under pressure. Such substances must be kept away from the concentrator, tubing, connections and all other oxygen equipment. • WARNING: Do not use any lubricants on the concentrator. •...
  • Page 6: Description Of The Concentrator

    Description of the Concentrator Oxygen Concentrator Components Figure 1: Oxygen Concentrator Components 1 – Flow Meter 6 – Humidifier Bottle Hose Set the flow rate of oxygen by adjusting 7 – Humidifier Bottle the knob. To minimize respiratory discomfort, use 2 –...
  • Page 7 Standard Accessories Humidifier Bottle Qty. 1 Humidifier Bottle Adapter Assembly Qty. 1 Cannula Qty. 1 If replacement accessories are needed, please contact Direct Supply for a list of accessories compatible with this concentrator. 1-800-634-7328 DirectSupply.com...
  • Page 8 Description of the Concentrator (cont.) Symbols and Descriptions Symbol Meaning Symbol Meaning Alternating current Refer to instruction manual Class II Type BF applied part Equipment OFF (power) ON (power) No open flame; Circuit Breaker Fire, open ignition source and smoking prohibited Height Do not expose to direct sunlight Date of...
  • Page 9: Unpacking The Concentrator

    Unpacking When unpacking concentrator, check for any obvious damage to the carton or its contents. If damage to the concentrator is evident, notify Direct Supply. Remove all loose packing from the carton. Carefully remove all the components from the carton.
  • Page 10: Initial Setup Of The Concentrator

    Initial Setup of the Concentrator Initial setup without humidifier bottle: 1. Remove the cannula from the plastic packaging 2. Connect the cannula to the oxygen outlet on the concentrator 3. Plug the concentrator into a 120V AC power source 4. Turn the concentrator on by pressing the power switch (“ | ” indicates the power is on, “...
  • Page 11: Using The Concentrator

    Inspect the concentrator for damage prior to each use. If damage is observed or functionality is in question, DO NOT use and contact Direct Supply for assistance. Turn the concentrator on by pressing the power switch so the “I” symbol is pressed in.
  • Page 12 Using the Concentrator (cont.) Testing the Safety Features of the Concentrator: Pressure Safety Valve Testing With the concentrator running, plug the oxygen outlet with your finger and verify that the pressure safety valve opens after 5 seconds, gas is released, and the pressure valve closes.
  • Page 13: Maintenance

    Maintenance • WARNING: Power off and unplug the concentrator prior to performing preventive maintenance. • WARNING: Do not perform preventive maintenance while the resident is using the concentrator. If used in a clean environment, the concentrator typically requires no filter cleaning or changes for one year. More frequent cleaning and filter changes may be required if: •...
  • Page 14 Maintenance (cont.) Cleaning the Optional Humidifier Bottle Replace the water in the humidifier bottle every day. Clean the humidifier bottle weekly. • Wash with a mild detergent • Rinse with water • Completely dry before returning to service Disinfecting the Optional Humidifier Bottle •...
  • Page 15: Troubleshooting

    2. Move concentrator at blocked air intake. least 4" (10 cm) away from walls, draperies, furniture or similar objects. 3. If condition persists, contact Direct Supply for service. Concentrator stops 1. Low pressure alarm. 1. Clean or replace filters. working, red status 2.
  • Page 16: Specifications

    Specifications Power supply: AC120V, 60Hz; Current: 3.5A; Power: 390VA Sound level: ≤ 50dB (A) Maximum recommended flow: 5L/min Flow Range at Outlet Pressure of zero: 0.5 - 5L/min Flow Range at Outlet Pressure of 7 kPa: 0.5 - 5L/min Change in maximum recommended flow when back pressure of 7 kPa is applied: <...
  • Page 17 16 Oxygen Output Temperature: Less than ambient temperature +11°F (6°C) 17 Cannula/Oxygen Tubing: To prevent folding or kinking of oxygen hose, do not use cannula longer than 6' (2m) or oxygen hose longer than 50' (15.2m) (non-flattening). 18 Storage and Transport Conditions: •...
  • Page 18: Compliance

    Compliance Guidance and declaration of manufacturer - Electromagnetic Emission The A5LC-1 Oxygen Concentrator is intended for use in the environment specified below. The purchaser of the A5LC-1 Oxygen Concentrator should ensure that the unit is used in such an environment. Emission test Compliance Electromagnetic Environment Regulations...
  • Page 19 Guidance and declaration of manufacturer - Electromagnetic Immunity The A5LC-1Oxygen Concentrator is intended for use in the electromagnetic environment specified below. The purchaser of the A5LC-1Oxygen Concentrator should ensure that the unit is used in such an environment. Immunity IEC 61000-4-2 Test Compliance Level Electromagnetic Environment Level...
  • Page 20 Compliance (cont.) Guidance and declaration of manufacturer - Electromagnetic Immunity The A5LC-1 Oxygen Concentrator is intended for use in the electromagnetic environment specified below. The purchaser of the A5LC-1 Oxygen Concentrator should ensure that the unit is used in such an environment.
  • Page 21 Recommended separation distances between portable and mobile RF communication equipment and the A5LC-1 Oxygen Concentrator. The A5LC-1 Oxygen Concentrator is intended for use in an electromagnetic environment in a controlled RF environment . The purchaser of the A5LC-1 Oxygen Concentrator can help to prevent electromagnetic interferences by maintaining minimum distances between the portable and mobile RF communication equipment (transmitters) and the A5LC-1 Oxygen Concentrator as recommended below, according to the maximum output power of the communication equipment.
  • Page 22: Limited Warranty

    Limited Warranty We offer to you, as the original purchaser, a warranty for the Direct Supply Attendant ® Oxygen Concentrator. Our warranty applies for the limited warranty period stated below. If any device or device part listed below is defective in material or workmanship during the applicable limited warranty period, we will repair or replace it at our cost.
  • Page 23: Customer Service

    Oxygen Concentrator and enjoy outrageous customer service. If you have any questions about the oxygen concentrator you have purchased or would like to request warranty service, please contact: Direct Supply Equipment & Furnishings at 1-800-634- 7328, 6767 N. Industrial Road, Milwaukee, WI 53223, SalesSupport@DirectSupply.com.
  • Page 24 Distributed by Direct Supply Manufacturing, Inc. 6635 N Industrial Road, Milwaukee, WI 53223. © 2020 Direct Supply Manufacturing, Inc. All Rights Reserved. Direct Supply , Attendant , and all associated logos are the registered ® ® trademarks of Direct Supply, Inc., used under license.

Table of Contents