5.5 Basic Settings

Function
Group
UNIT
ZERO
GET'Z
BASE
DISP
TAU
BASE
DESI

5.6 Settings for Output - 2x Switch Output

• Hysteresis function
The hysteresis function enables two-point control via a hysteresis. Depending on the
temperature (T), the hysteresis can be set via the switch point (SP) and the switch-back
point (RSP).
• Window function
The window function enables the monitoring of a process temperature range.
• NO contact or NC contact
This switch function is freely selectable.
• Delay times for switch point (SP) and switch-back point (RSP) can be set in
increments of 1 second to filter out undesirable temperature peaks of short duration or
high frequency.
User Manual - ETS Series Digital Temperature Sensors
Function
Technical unit
Configure zero
point
Accept zero point 0 . 0
Display
Damping: display
value, output
signal
DESINA
Settings
°C
Select technical unit: °C, °F, K
°F
Factory setting: °F
K
Position adjustment: within ±18ºF/K
0 . 0
(±10ºC) of the upper range limit
No settings possible (not available in
XT-SOFT)
PV: measured value display
PVRO: measured value display rotated
PV
180°
PVRO
SP: set switch point display
SP
SPRO: set switch point display rotated
SPRO
180°
OFF
OFF: display off
OFFR
OFFR: display off rotated 180°
Factory setting: measured value PV
Measured value damping with regard to
display value and output: 0 (no damping)
0 . 0
or 9 to 40s (in increments of 1 second)
Factory setting: 0s
PIN assignment of the M12 connector
is in accordance with the guidelines of
NO
DESINA
YES
Factory setting: No