User Manual - ETS Series Digital Temperature Sensors
5.9 Programming with XT-SOFT Software
The ETS Series can be programmed using XT-SOFT programming software, available
as a free download at www.automationdirect.com, and an XT-USB configuration cable
(purchased separately). The operating options listed in the previous "On-Site Operation"
section are available via XT-SOFT except as noted.
Note: XT-SOFT version 1.27.15.0
or later required for use
with the ETS Series.
5.10 Additional Operating Options
In addition to the operating options listed in the previous "On-Site Operation" section,
the XT-SOFT software provides the following read-only information.
Function Group
Service Setting
Identification
6 Diagnostics and Troubleshooting
6.1 Diagnostic Information on Local Display
If an error in the device occurs, the color of the status LED changes from green to red
and the digital display illumination changes from white to red. A status LED flashing red
and green signals a warning. The display shows:
14
ETS Digital Temperature Sensors Rev. 1
XT-USB
Con guration
Cable
ETS Series
Description
Number of switch changes for output 1
Number of switch changes for output 2
Device status
Tag number
Order code
Limit switch serial number
Sensor serial number
Electronics serial number
Device release (change status)
Hardware version
Software version
External power
not required for
programming via
XT-USB & XT-SOFT
External power
not required for
programming via
XT-USB & XT-SOFT