Dimensions Code Description Dimensions 343054 Wall Mounted Infrared- Battery See image Pegler Yorkshire reserve the right to change specifications Guarantee 5 Year Guarantee Luxury Taps and Mixers Pegler Customcare 5 Year Guarantee - Terms and Conditions Product are subject to a 5 year guarantee that is between Pegler and the final purchaser of the product.
Page 2
Pegler Yorkshire Group Ltd, St Catherine's Ave, Doncaster, S Yorkshire, DN4 8DF Telephone: Phone +44 (0) 844 243 4400 Fax: +44 (0) 844 243 9870 Website: www.pegleryorkshire.co.uk Registered office : Pegler Yorkshire Group Ltd, St Catherine's Ave, Doncaster, S Yorkshire, DN4 8DF Company no : 00401507...
WHAT YOU SHOULD HAVE IN YOUR PACKAGE TAP BODY 343054 343052 343055 343053 343050 343051 CLAMPING RODS BACK PLATE 343050 343054 343052 343051 343053 343055 FIBRE CLAMPING MOUNT INLET HOSE 343054 WASHER NUTS BRACKET 343055 343052 343053 343051 343050 CONDUCTIVE BRASS SHORT SOLENOID...
Page 5
1. IMPORTANT Read this manual before installation 2. INTRODUCTION Performa Electronic Sensor Taps are available with two types of Sensing Technology: 1. Optical Sensor taps use infrared light to detect a user’s hands in the area beneath around the whole tap body that can detect a the spout.
Page 6
Screw clamping rods (B) into tap (A). Make sure rods are fully secure and aligned. Fit back plate (C) over rods. Ensure Performa marking is facing towards the spout outlet. Screw the inlet hose (D) into remaining hole. Screw in fully to seal.
Page 7
WALL / SINK Fit rods and inlet hose through the WORKTOP hose and rods. Fit bracket (F), ensuring the notches align with the rods. SHOULD LOOK LIKE THIS... Use long clamping nuts (E) to tap together. Tighten using either a box spanner or adjustable spanner.
Page 8
5. INSTALLING WATER CONNECTION DO NOT REMOVE! BETWEEN CONNECTIONS CAN ROTATE ACCESS RECOMMENDED UPSTREAM CONNECTIONS PERFORMA TAP damage to the solenoid valve. maintenance. If the supply pressure is greater than 5 bar, it is recommended that a pressure reducing valve is...
Page 9
6. INSTALLING ELECTRICAL CONNECTION CONNECTION BE USED TO SECURE THE IT IS RECOMMENDED THAT CONNECTED TO THE MAINS SWITCH MUST BE RATED AT 3 AMPS. ENSURE MAINS PRE-FITTED IN 1. Site the mains power supply box close to the inlet to the tap and solenoid valve. Use the length of the sensor cables for guidance.
Page 10
1. Site the battery box close to the inlet to the tap and solenoid valve. Use the length of the sensor cables for guidance. 2. Secure the box to the wall or support. Where possible position the battery box away from water 3.
Page 11
SWITCH 1. Site the battery box close to the inlet to the tap and solenoid valve. Use the length of the sensor cables for guidance. 2. Secure the box to the wall or support. Where possible position the battery box away from water 3.
Page 12
7. OPERATING ELECTRONICS MAINS If using a mains supply box turn the power supply switch on. If you are using a battery box insert the supplied battery. After that switch the water on. watertight in their respective glands. does not reliably detect the presence of a user, please contact technical support for guidance on how to adjust the sensor range.
Page 13
7b. CAPACITIVE SENSOR TAP Fit the battery into the battery box, then switch the water on. watertight in their respective glands. does not reliably detect the presence of a user, please contact technical support for guidance on how to adjust the sensor range.
8. MAINTENANCE 9. IMPORTANT DETAILS Maximum Static Pressure 6.0 Bar Optimum Operating Pressure 2.0 - 2.5 Bar Minimum Flow Pressure - Hot 0.2 Bar and Cold Temperature Range C - 60 Customer Reference Data must be completed and be stored carefully for warranty purposes.
The sensor has 2 cables leading out of the rear of the lug; these cables should never be extended (Unless the correct extension cables are used.) All Performa electronic taps conform to relevant parts of the following directives: NOTE: All electrical installations must comply...
Page 17
12. TEMPLATE Backplates only Deck mount Wall mount Wall mount 23.4...