When the meter displays RUN, the RAMP is on.
When the meter displays HOLD or Hb, the RAMP blinks.
Note: When the CTrl is set at rSP, and the curve goes through the slope, the RAMP is on.
(2)display while running
When the meter displays RUN, Hb or HOLD, press PAR. The lower screen display the code
r1,d1,r2,d2,......Hb and the code of display code.
(3)Display of remaining time
When the meter is on flat section d1or d2, the value displayed under the parameter code is the
remaining time, not the total running time.
(4)display of setting
When the meter is in the state of run ,Hold or Hb, the lower screen shows the running setting
instead of the basic setting. The basic setting displays under the SP parameter code.
When the meter is in the state of ldIE, the lower screen displays the basic setting.
2. Modification of parameters when the curve procedure runs.
a. When the meter runs, we can't modify the curve program parameter LC,r1, L1, d1, r2,
L2.d2...... But other parameters can be modified and saved.
b. When the meter pauses, the modification of LC,r1,L1,d1,r2,L2.d2......is valid only in this
running, and not saved. Other parameters all can the modified and saved.
c. When the meter stops, LC,r1, L1, d1, r2, L2.d2......and other parameters can be modified and
saved.
d. What to do if there is a power-off while the meter is working? At this moment, the meter will
record and save the current parameter and running state. Once the power is on, the meter will
continue the program from this point, instead of restart from the beginning.
e. What to do when the curve program is over? Then the meter will deal with it according to the
settings of (P, End). When P.End is set at OFF, the meter stops outputting and the programme is
over.
The following chart only for reference: