3. Remove the access plate on the exhaust blower housing by removing the (6) ¼" hex head screws.
Remove the plate and gasket and keep these parts for reinstallation. If the gasket material is
deteriorated or damaged replace it when reinstalling the cover plate. Clean the combustion blower
with the bottle brush or vacuum.
NOTE: Take care to prevent damaging the combustion blower impellers.
Yearly Maintenance (or Every Ton of Pellets) - Clean the Convection Blowers
1. There are two convection blowers on this appliance, one on each side. The rear panel must be
removed to access the blowers. Remove the (3) 5/16" screws along the top and (3) additional screws
along the bottom of the rear panel. Lift up on the panel using the handle on the top edge to
disengage the bottom of the panel from the floor of the stove.
© Travis Industries
Maintenance
Blowers
12/18/20 - 1550
Impellers are accessible for
maintenance without
removing blower.