8
Room climate - measured values
The measuring device features a fold-out sensor that
measures the ambient temperature and relative humidity
while also calculating the dew point temperature. By folding
out the sensor, the improved through-flow of air speeds
up the measurement procedure.
When changing location and/or where there are
!
large differences in the room climate, it is important
to give the measuring device time to adapt until
the measured values in the display have stabilized.
!
The measured ambient temperature and relative humidity values are automatically updated
and is not dependent on when the trigger button is pressed.

Condensation warning

9
The dew point temperature is the point the temperature must drop below for the air to
precipitate its water vapour in the form of droplets, mist or dew. Condensation water
therefore occurs for example when the temperature of an inside wall or window reveal
is lower than the dew point temperature of the room. These areas are then damp and
are a breeding ground for mildew/mould with possible material damage.
The CondenseSpot Pro calculates the dew point with the integrated sensors for ambient temperature
and relative humidity. At the same time, the surface temperature of objects is determined with the aid of
infrared temperature measurement. By comparing these temperature it is possible to identify areas that
are exposed to the risk of condensation moisture. The condensation moisture indicator (b) displays the
result in the form of a bar graph, supported by visual and acoustic signals indicating the high probability
of condensation moisture occurring.
No risk of
condensation moisture
The condensation moisture indicator (b) is shown in all modes.
The device therefore constantly shows the risk level of condensation moisture.
The visual and acoustic signals can be turned off by pressing the alarm function button (3).
The symbols "
" (m) and "
Slight risk of
condensation
moisture „ "
symbol flashing
" (n) indicate whether the alarm function is active or not.
CondenseSpot Pro
Risk of condensation
moisture „ " symbol
flashing with
acoustic signal
15