Hh310 - Electro Industries EM-WE1025H Installation Manual

Warmflo equipped electric duct heater
Table of Contents

Advertisement

ELECTRO INDUSTRIES, INC.
MONTICELLO, MN 55362
WARMFLO SYSTEM
HP W/ EM-WE
HH310
REV.G 03-07-07
NOTES:
1. PER HP MFG. HOOK-UP
2. SINGLE CONTROL LINE.
3. 3-WIRE CABLE (EACH), PROVIDED.
4. IF FULL ELECTRIC IS DESIRED, CONNECT TO "E" TAB.
5. HP ODT, 2 CHOICES:
- USE MFG. PROVIDED WITHIN OUTDOOR UNIT
- USE WARMFLO SENSOR & CONTROLLER, ADD RELAY (SEE
DETAILS A, B)
HP
COIL
BLOWER
EM-WE SERIES
DUCT HEATER
PACKAGE
T5
TEMPERATURE
A1
EL ON
LED6
UPCB5615
CS
MINIMUM
WARM
AIR
SW1
LED3
LED4
LED2
LED1
J1
SW4
CAL.
ODT
SW3
COM
RED
OT
ST
HP-ODT
J3
J2
LED5
T4
C
T6
T1
T2
E
Y
T3
R
SW2
LED6
EL ON
T
E
M
P
E
R
A
T
U
R
E
S
W
5
WARM AIR
DETAIL A
SCALE 4:1
CAL.
SW4
E
T6
COM
OT
RED
ST
T4
C
T1
T2
Y
T3
R
DUCT
OUTSIDE
WHT
RED
BLK
HP-ODT
E
HP ODT
SEE DETAIL B
2ND STAGE
BLOWER
EMERGENCY
GREEN
SEE MANUAL
(DO NOT USE)
1
4
(DO NOT USE)
DEFROST
2
24VAC HOT
24VAC COMMON
REVERSING VALVE
1ST STAGE
ROOM THERMOSTAT
RED
BLUE
YELLOW
ORANGE
OUTDOOR UNIT
1
R
C
Y
O
ODT
5
3
BLK/YEL
GRAY
24VDC OR
24VAC
BLU/YEL
ORG/BLK
YEL/GRN
R
HP-ODT
EE-5053
5
5
DETAIL B
EM-WE
(CONTROL BOARD)
Y
Y