Electro Industries EM-MB01 Installation & Operating Manual

Packaged make-up air

Advertisement

Quick Links

---------------------------------------------------------------------------------------
Installation & Operating Manual
---------------------------------------------------------------------------------------
Packaged Make-Up Air
Included With This Product
Permanent washable air filter
Powered inlet damper
Temperature sensor
Chain kit for ceiling installations
Other Requirements
Turn-on device (switch closure) connected to R & W (Class II wiring)
High voltage wiring
Fresh air intake wall vent
Inlet/outlet ductwork
Application
This product aids in preventing building depressurization where there is an exhaust blower/fan, coupled
with a tight building envelope.
Conforms to: UL STD.UL1995
Certified to: CSA STD.C22.2#236
DO NOT DESTROY THIS MANUAL. PLEASE READ CAREFULLY AND KEEP IN A SAFE
PLACE FOR FUTURE REFERENCE BY A SERVICE TECHNICIAN.
12/30/2020
Heat Models EM-MB01 & EM-MB02
EI916

Advertisement

Table of Contents
loading

Summary of Contents for Electro Industries EM-MB01

  • Page 1 --------------------------------------------------------------------------------------- Installation & Operating Manual --------------------------------------------------------------------------------------- Packaged Make-Up Air Heat Models EM-MB01 & EM-MB02 Included With This Product  Permanent washable air filter  Powered inlet damper  Temperature sensor  Chain kit for ceiling installations Other Requirements  Turn-on device (switch closure) connected to R & W (Class II wiring) ...
  • Page 2: Table Of Contents

    Table of Contents Page Product Description Handling & Storage Placement & Mechanical Information Product Configurator Specification Tables Dimensional Drawings Safety Consideration Installation Requirements Installation Overview Mechanical Installation Electrical Installation Control Wiring High Voltage Hookup Basic Setup Operational Indicators Troubleshooting Routine Maintenance Replacement Parts Drawings UAW873...
  • Page 3: Product Description

    Product Description This is a self-contained package with a permanent (washable) air filter, electric heating elements, modulating element temperature control, powered damper and fan. This product has been designed specifically for outside air inlet. All models include WarmFlo electronic outlet temperature sensor and associated control circuitry to modulate the electric elements for a fixed outlet temperature.
  • Page 4: Product Configurator

    60° F 50° F 40° F 30° F Specifications Internal Motor Motor Max Fuse/ Duct Model Btu/h Amps Phase Voltage HACR Connection Static EM-MB01-120-1-06 3,412 1/18 1-50/60 Hz 0.03” 6” EM-MB02-120-1-06 5,459 13.3 1/18 1-50/60 Hz 0.03” 6” 12/30/2020 EI916...
  • Page 5: Dimensional Drawings

    Dimensional Drawings 12/30/2020 EI916...
  • Page 6: Safety Consideration

    Hazards or unsafe practices could result in property damage, product damage, severe personal injury and/or death. 2. At Electro Industries the safety of the installer and the end user is of highest priority. Remember, safety is the installer’s responsibility and the installer must know this product well enough to instruct the end user on its safe use.
  • Page 7: Installation Overview

    Installation Overview This Make-Up Air unit contains interface/logic devices, outlet temperature sensor, power open/spring close damper, permanent washable filter and fan motor. Based on the application, other system components may be required to make your system operate as desired. These components must be provided by the installing contractor.
  • Page 8: Mechanical Installation

    Mechanical Installation This product is designed for zero clearance, but use the following mounting and spacing criteria: 1. Unit can be installed vertically or horizontally. When vertical, inlet must face down. 2. Observe the airflow direction decal and the inlet decal. 3.
  • Page 9 Horizontal installation – Ceiling Mount Vertical Installation – Wall Mount Horizontal installation – Wall Mount Option A: Cover Facing Down Option B: Cover Facing Side 12/30/2020 EI916...
  • Page 10: Electrical Installation

    Electrical Installation Temperature Sensor Heated air outlet temperature sensor is included. Without proper installation of this probe the Make- Up Air unit will not operate correctly. The sensor probe/cable is attached to the control board. However, the sensor probe must be installed external to this unit.
  • Page 11: High Voltage Hookup

    High Voltage Hookup Service Panel Circuit Breaker(s) Sizing – based upon unit size, the specification page shows appropriate service size requirements based on UL and NEC code. Note: These two models require 120VAC source (not 240). Source Power – route and install proper current carrying conductors as per local code requirements, from service panel.
  • Page 12: Basic Setup

    Basic Setup Temperature Set Point – Located on the control board is a dial labeled SW1. This dial is used to set the desired output temperature. Setting the desired output temperature is completed in two steps. See Figure 1 for temperature ranges. ...
  • Page 13: Operational Indicators

    Operational Indicators Green LED – on control board.  Full on = low voltage present and okay, micro controller is functioning, etc.  One pulse = electric heating element is active (set point is still controlling actual element on/off).  Two pulses = bad outlet temperature sensor.
  • Page 14: Troubleshooting

    Troubleshooting 1. This product contains several interference suppression components, but as an electronic logic product unpredictable and unusual transients or interferences may sometimes cause strange results. If this product is acting strange, turn off the source power, count to 10, and reenergize. 2.
  • Page 15: Routine Maintenance

    Routine Maintenance Filter – this unit includes an air filter which is a permanent and washable filter. Suggest at least twice per year removing filter and using standard household water to back flush collected dust/debris.  Remove screws from small door, opposite the hinged door end ...
  • Page 16 DECAL + TITLEBLOCK DO NOT PRINT AS DECAL...
  • Page 17 Limited Product Warranty Effective November 1, 2009 Electro Industries, Inc. warrants to the original owner, at the original installation site, for a period of two (2) years from date of original purchase, that the product and product parts manufactured by Electro Industries, Inc.
  • Page 18 The decision whether to repair or, in the alternative, replace products or product parts shall be made by Electro Industries, Inc. or its authorized representative.

This manual is also suitable for:

Em-mb02

Table of Contents