Electro Industries EM-WX02-240-1-08 User Manual

Electric make-up air with warmflo controller

Advertisement

ELECTRIC MAKE-UP AIR
2.5 kW, 240-Volt, Single Stage, 8" Duct Section
Specific Application
 Air exchanger, temperature boost
 Make-up air
 Temperature comfort boost
Comment
This module is a heating element and controller to "temper" the inlet air and bring it
to a comfortable level. This unit contains a built in controller with duct sensor to
modulate the electric element (part of this unit) using only the required electric
energy to reach comfort level. This is more than basic on/off duct heater.
Drawings:
UAW890
UAW892
XX017
10/19/2017
With WarmFlo
Models:
EM-WX02-240-1-08
EM-WX05-240-1-08
5 kW, 240-Volt, Single Stage, 8" Duct Section
EM-WX10-240-1-10
10 kW, 240-Volt, 2-Stage, 10" Duct Section
®
Controller
EI913

Advertisement

Table of Contents
loading

Summary of Contents for Electro Industries EM-WX02-240-1-08

  • Page 1 ELECTRIC MAKE-UP AIR ® With WarmFlo Controller Models: EM-WX02-240-1-08 2.5 kW, 240-Volt, Single Stage, 8” Duct Section EM-WX05-240-1-08 5 kW, 240-Volt, Single Stage, 8” Duct Section EM-WX10-240-1-10 10 kW, 240-Volt, 2-Stage, 10” Duct Section Specific Application  Air exchanger, temperature boost ...
  • Page 2 “turning the unit on”. Minimum airflow relates to temperature rise needs or design, Table 2 – CFM Chart, provides these CFM numbers. FIGURE 1 Table 1 Electrical Requirements Nameplate Model Btu/h Duct Collar Current* EM-WX02-240-1-08 8,500 10.5 8” EM-WX05-240-1-08 17,000 8” EM-WX10-240-1-10 34,000 10”...
  • Page 3: Installation Requirements

    Electro Industries, Inc., cannot be held responsible for field modifications, incorrect installation, and conditions which may bypass or compromise the built-in safety features and controls.
  • Page 4: Electrical Hookup

    Electrical Hookup 240-volt source – from the model number and nameplate determine KW size and amp draw. According to local codes, building type, wiring length, etc. use appropriate wiring conductor size and source circuit breaker. Connect to the terminal block. Grounding –...
  • Page 5: Operational Tips

    Operational Tips Outlet Temperature Setting The inside circuit board contains two screwdriver switches marked Ø through 7. Adjust them to select the desired set point for your application. EX: Ideal set point = 86° Mode Dial would be set to #4 Warm Air Dial would be set to #0 NOTE: MODE DIAL setting # 7 is not applicable to this product Mode Dial Temperature Range Options...
  • Page 8 Limited Product Warranty Effective November 1, 2009 Electro Industries, Inc. warrants to the original owner, at the original installation site, for a period of two (2) years from date of original purchase, that the product and product parts manufactured by Electro Industries, Inc.
  • Page 9: Conditions And Limitations

    The decision whether to repair or, in the alternative, replace products or product parts shall be made by Electro Industries, Inc. or its authorized representative.