Safety Precautions ........................3 Navigating the Manual ........................3 Getting Started ......................... 4 Unpack and Inspect ........................4 Setup the CAV 4.1 ......................... 5 Connect Hoses .......................... 6 Fill the Bath ..........................8 Drain the Bath ......................... 12 Connect Cables ........................15 Set Bath Temperature (Touchscreen) ..................
Page 6
VISCPRO II Software Interface ....................44 Manage User Accounts (VISCPRO II / CAV 4.1 GUI Touchscreen) ..........45 Log In ............................46 Change Password ........................46 Setup and Edit User Accounts ....................46 Logout ............................ 47 Connect VISCPRO II to the CAV 4.1 ..................... 47 VISCPRO II Instrument Set Up ..................
Page 7
Shipping Notification ......................67 List of Figures Figure 1 — Complete CAV 4.1 System Setup ..................5 Figure 2 — Tubing Connections (Rear Close Up) ................6 Figure 3 — Back of CAV 4.1 ....................... 8 Figure 4 — Filling and Draining the Bath ................... 9 Figure 5 —...
/s (cSt) and 10,000 mm /s (cSt) from 20 °C to 150 °C, with available options. The CAV 4.1 combines CANNON quality and reliability with modern design and unique features to enhance lab productivity, reduce costs, and improve data quality.
Refer all service and repairs to qualified personnel. Navigating the Manual Since the CAV 4.1 uses both a touchscreen interface on the instrument and the VISCPRO II computer software application, the instructions are broken into sections for each type of controlling software. The header of each section notes CAV 4.1 GUI Touchscreen...
CAV® 4.1 Operator's Manual Getting Started This chapter covers all steps necessary to set up, calibrate, and run a sample on the CAV 4.1. The procedures are intended to be performed in the order written. These are basic, simplified procedures designed to familiarize an operator with the instrument, with more detailed instructions provided in following sections.
¼ “ wrench ---- Setup the CAV 4.1 Initial setup of the CAV 4.1 involves connecting the hoses and cables, and filling the bath with silicone bath fluid. Figure 1 — Complete CAV 4.1 System Setup CANNON Instrument Company® | Getting Started...
6 mm blue FEP tubing (15 ft) Connect Hoses Assemble the CAV 4.1 on a secure surface with sufficient room behind the instrument to maintain a clear airflow and allow for unimpeded connection of the solvent inlet and waste outlet tubing.
Page 17
1. Place the CAV 4.1 on a solid, level workbench located near a MAINS AC power connection capable of providing sufficient current (10 A at 115 V ) to the CAV 4.1. Depending on the materials tested, solvent used, and laboratory regulations, the work area may also need to be equipped with a ventilation system.
Figure 3 — Back of CAV 4.1 10. Connect the waste tubing to the waste receiver. 11. Measure, cut, and install the 6 mm blue FEP tubing as exhaust tubing. Fill the Bath The temperature bath must be filled with the appropriate silicone fluid prior to operation. The viscosity of the fluid depends upon the temperature of the bath during most operations.
Bath Drainage Receptacle Procedure 1. Turn off power to the CAV 4.1 instrument and let the bath cool to room temperature. 2. Lift the hood to access the top of the bath. 3. Remove the float from the top of the bath and set aside. This provides the opening to fill the bath.
5. Using the funnel, fill bath with the appropriate silicone bath fluid to the appropriate fill line on the bath. The top line is for lower temperatures (100 °C) and the bottom line is for higher temperatures (135 °C and above). Refer to Figure 7. | CAV 4.1 Operation Manual...
Figure 7 — Filling Bath with 10 cSt Silicone Fluid Top Fill Line Figure 8 — Bath Filled to Top Fill Line CANNON Instrument Company® | Getting Started...
2. Lift the CAV 4.1 hood to access the bath. It flips up, as shown in Figure 9. Figure 9 — Lift the CAV 4.1 Hood 3. Remove the front panel of the CAV 4.1 by gently pulling it away from the front of the instrument, as shown in Figure 10. Set the front panel aside.
Tube covers the end of the nozzle Figure 11 — Hose Inserted Properly onto Bath Drain (with Close Up) 5. Insert the other end of hose into a silicone fluid bottle or appropriate bath drainage container. CANNON Instrument Company® | Getting Started...
Figure 13 — Open Drain with Allen Wrench and Close-Up 7. When the bath drain is completely open, the drain plug will rise out of the bottom of bath and no longer be flush with the bottom of bath. | CAV 4.1 Operation Manual...
2. Plug the power cord into the MAINS AC outlet at the work station. 3. (optional) Connect the CAV 4.1 to the network switch with one CAT cable. 4. (optional) Connect the network switch to the PC with a CAT cable and USB adapter.
Target temperature temperature temperature temperature Figure 16 — Main CAV 4.1 Screen 2. Click the Target Temperature field. A field entry screen opens as shown in Figure 18 and 19. Figure 17 — Temperature Settings Screen Figure 18 — Field Entry Screen 3.
4. From the main screen, click the current bath temperature button for the bath. This opens Temperature Calibration screen, as shown in Figure 21. Figure 20 — Temperature Calibration Screen 5. Click the Reference Temperature field. A field entry screen opens. CANNON Instrument Company® | Getting Started...
Figure 21 —Green Checkmark for Entry Submission 7. Select Calibrate, wait for the system to save the adjustment, and then click to return to the Back main screen. 8. Remove and clean the thermometer, and then store safely. | CAV 4.1 Operation Manual...
Set Vacuum and Pressure (Components) Set the vacuum and pressure of the CAV 4.1 before running the instrument. Use the following procedure to access the vacuum and pressure knobs within the instrument. Table 8 — Tools and Materials Required Description Part Number Assembled CAV 4.1...
Figure 24 — Pull Out Chassis while Pulling Up Both Access Pins 4. Pull latch on side panel to open the right bath control wing. When the latch is open, the bath control wing swings out. | CAV 4.1 Operation Manual...
Figure 25 — Side of Chassis with Latch, with Close up of Latch 5. The bath control wing swings out, allowing access to the Vacuum and Pressure knobs. Adjust as necessary. Figure 26—Side View of Open Bath Control Wing CANNON Instrument Company® | Getting Started...
Vacuum Control Pressure Control Figure 28 — Front View of Bath Control Wing with Vacuum and Pressure Knobs 6. Repeat the steps in reverse order to slide the chassis back into place and commence operation. | CAV 4.1 Operation Manual...
2. From the bath screen, click the Service button. This opens the Service menu options. Refer to Figure 31. Figure 30— Services Menu 3. Click Adjust Pressure/Vacuum. Follow the instructions prompted on the screen, as shown in Figure CANNON Instrument Company® | Getting Started...
Adjust the Default Wash Settings (Touchscreen) Verify and adjust the default wash settings prior to running a wash for the first time. The CAV 4.1 wash settings are defined in the method settings of the last Note: run test. When starting the CAV 4.1 from a complete shutdown, it does not reference the last run test and uses the default wash settings.
Hence, prior to training the sensors or running tests, it is vital to first run a wash through the CAV 4.1. 1. Insert an empty vial into position 1 of the carousel.
CAV 4.1 runs at that temperature again. Retraining for a particular temperature is only necessary when the viscometer tube is changed or if sensor performance changes over time. 1. Insert an empty vial into position 1 of the carousel.
Review and Export Data (Touchscreen) Once a test completes, the results can be exported to a USB drive in CSV format. 1. From the main screen, click the Results button. 2. Review the results. CANNON Instrument Company® | Getting Started...
Page 38
A field entry screen opens. 4. Enter the sample file name. Then click the green checkmark to submit it. Save As window opens. 5. Select the desired location to save the data file, then click Save. | CAV 4.1 Operation Manual...
The preheating option on the CAV 4.1 is controlled via tube settings and can be used on either carousel. Prior to starting the process of activating preheating, ensure that the carousel is filled with the provided metal sleeves.
Page 40
Sample Cup Heater Duty Cycle Figure 41 — Sample Cup Heater Duty Cycle 5. Press Save. If not saved, red lights appear on-screen to indicate changes have been made that are not saved. Refer to Figure 43. | CAV 4.1 Operation Manual...
Page 41
– do not touch. Do not allow any metal items (other than the metal vial sleeves) to touch the glass. 7. Go back to the main screen to exit the Preheating options. CANNON Instrument Company® | Sample Preheating...
If instrument is equipped with TE cooling option, follow the instructions outlined below in order to engage the CAV 4.1 in thermoelectric bath cooling. Always use proper laboratory procedures and caution when working with the CAV 4.1 instrument.
Page 43
Figure 47 — TE Cooler Indicator Lit In order to troubleshoot and verify the TE Cooler is working properly, open the hood to ensure the blue light is lit. If not, contact CANNON Instrument Company service for assistance at service@cannoninstrument.com or 814-353-800.
Page 44
Blue Indicator Light Figure 48 — Blue Indicator Light for Proper TE Cooling | CAV 4.1 Operation Manual...
VISCPRO and CANNON instruments. Figure 49 — Closed Network Settings Connect Equipment All CANNON CAV systems and the PC (with USB 2.0 to Ethernet adapter) connect to the network switch using standard CAT 5e/6 cables. Table 9 — Tools and Materials Required...
3. Connect a CAT cable from the Ethernet adapter to the network switch. 4. Connect CAT cables from each CAV 4.1 to the network switch. Install VISCPRO II There are no configurable options in the VISCPRO installation routine. Insert the USB and follow the on- screen prompts.
Page 47
6. Right-click the connection and select Properties. The Connection Properties window opens. 7. Uncheck Internet Protocol Version 6 (TCP/IPv6). 8. Double-click Internet Protocol Version 4 (TCP/IPv4). The Internet Protocol (TCP/IP) Properties window opens. CANNON Instrument Company® | Connecting with VISCPRO II...
Enter 1982 in the port field. • Select connection. Click Next. Allow the • Check all boxes: Domain, Private, and Public. Click Next. • In the Name field, enter Viscpro_IN. Click Finish. 4. Configure an outbound rule: | CAV 4.1 Operation Manual...
Page 49
Select Custom. Click Next. • Select All programs and click Next. • Change Protocol Type to ICMPv4. • Click Customize. • Select Specific ICMP types. • Check Echo Request and click OK. Click Next. CANNON Instrument Company® | Connecting with VISCPRO II...
CAV Registry Settings The following registry keys are set up at CANNON prior to shipping and do not need to be adjusted for the initial installation. However, when reconfiguring a network or adding an additional CAV 4.1 to your...
Page 51
Registry Key CAV 4.1 GUI Default Description value Address Instrument ID Instrument Instrument name Serial Number Serial Text string Instrument serial number Number EthernetPortNumber 1982 TCP port on which VISCPRO listens available CANNON Instrument Company® | Connecting with VISCPRO II...
Common instrument settings, method templates, and equipment status are shared between the programs. The operating status of the CAV 4.1 is shown on the left-most button of the main screen menu of the CAV 4.1 GUI (touchscreen). This button toggles between...
Page 53
Displays current activity Preheater temperature Displays current preheater temperature Run / Stop Click to start or stop a run Actions Wash Click to run a wash Pause Click to pause a run or wash CANNON Instrument Company® | In-Depth Operation...
VISCPRO II is a Windows® software program comprising the general interface application and instrument/analysis-specific modules. A typical VISCPRO II interface displays an open instrument window, analysis log, application specific status window, and general information status windows, as shown in Figure 57. Figure 56 – VISCPRO Interface Window | CAV 4.1 Operation Manual...
CAV 4.1 GUI Touchscreen) VISCPRO II and CAV 4.1 GUI user accounts are independent of each another. The VISCPRO II accounts are associated with the entire software installation and are not instrument specific. Both VISCPRO II and the CAV 4.1 GUI Touchscreen start with three default accounts, as described in Table 14.
Touchscreen: click Users > Change Manager Password. Because new accounts cannot be created using the CAV 4.1 GUI, this is the only option. 2. Type the new password into the appropriate fields. 3. Click or the select the green checkmark.
Users > Logout. Connect VISCPRO II to the CAV 4.1 VISCPRO II and the CAV 4.1 must be set up and communicating in order to attempt to establish a connection. Refer to Connecting with VISCPRO II. The preheat option is factory installed. This section is only applicable for Note: instruments with the preheating option installed.
CAV 4.1 Touchscreen, touch the Local Mode/Remote Mode button to toggle the instrument state to Remote. The icon turns green to indicate that the CAV 4.1 is found and communicating with VISCPRO II. 3. In the Menu, click and then Instruments.
Train the sensors whenever operating the CAV 4.1 bath at a new temperature. Once trained, the calibration values for a particular temperature are saved and will be recalled if the CAV 4.1 is set to run at that temperature again. Retraining for a particular temperature is only necessary when the viscometer tube is changed or if sensor performance changes over time.
Run a Sample Test (VISCPRO This procedure details how to run and configure various kinematic viscosity tests on the CAV 4.1 using VISCPRO II software. 1. Verify that the CAV 4.1 is running and has achieved steady-state temperature in the bath.
Page 62
You can copy the complete set of entries from one tray to another. • Restore Tray from Archive—restores a previously saved tray. • Archive—opens the archive to allow deleting saved Delete Tray from trays. 6. Click Run. The window opens. Select Trays | CAV 4.1 Operation Manual...
7. Select the trays to run. Click The CAV 4.1 begins running the selected trays. Additional samples may be added to the trays until the run completes. • Pause—opens a selection window. Pausing a tray "Now" immediately halts all actions for that tray.
40 °C to 50 °C 90 °C to 100 °C 50 °C to 60 °C 100 °C to 110 °C 60 °C to 70 °C 110 °C to 120 °C 70 °C to 80 °C > 120 °C 100% | CAV 4.1 Operation Manual...
Viscometer tube calibration values are associated with specific temperatures. A calibration must be performed any time the CAV 4.1 bath is operating at a new temperature. Once the tube is calibrated at a particular temperature, the instrument saves the C and E constant values. The values are then automatically recalled if the tube is run at that temperature again.
Method / Test Settings Method templates are stored in the CAV 4.1 registry. When VISCPRO II software connects with a CAV 4.1 instrument, the method templates in the instrument are pushed to VISCPRO II. Any changes made to the method templates in VISCPRO II synchronize with the instrument.
Time (sec) that solvent A is injected after bulb empties Solvent B Injection Time Time (sec) that solvent B is injected after bulb empties Solvent C Injection Time Time (sec) that solvent C is injected after bulb empties CANNON Instrument Company® | Advanced Setup...
Page 68
Time (sec) for a bulb 2 sample between when the tube vent is opened to atmosphere and the sample efflux starts Bulb 3 Vent Drain Time Time (sec) for a bulb 2 sample between when the tube vent is opened to atmosphere and the sample efflux starts | CAV 4.1 Operation Manual...
5. In the Date Filter tab, set the appropriate range for the data to be displayed. 6. In the Sample Filter tab, set the filters on the type of data to be displayed. 7. In the Report tab, select the data items to display (refer to Table 21): CANNON Instrument Company® | Advanced Setup...
Page 70
Adds the first 10 efflux times to the analysis {1,20} Efflux %d Adds the first 20 efflux times to the analysis Avg Efflux Average efflux time calculated using valid effluxes C constant of calibration E constant of calibration Saybolt Furol Seconds calculation | CAV 4.1 Operation Manual...
Page 71
8. Click OK. The software prompts user to save the analysis. • If selecting YES, the analysis is displayed after it is saved. • If selecting NO, the analysis displays, but is not saved. CANNON Instrument Company® | Advanced Setup...
• UI updater: this software is actually the complete UI updater program (UpdateUI.exe) that runs on the CAV 4.1. It is used to install the UI software and firmware updates. It is updated by copying it over the existing UpdateUI.exe.
8. After the CAV finishes its rebooting routine, power cycle the unit by completely turning it off using the power switch on the hood. Wait 10 seconds, and then turn it back on. Update the Controller Firmware Be careful not to touch any moving parts or live wires in the CAV 4.1. Warning: Note: A video of this procedure is available on CANNON’s YouTube channel.
Warning: ambient or a safe temperature. 1. Turn off the CAV 4.1 and allow the bath to cool to ambient/room temperature. 2. Drain the silicone bath fluid into a clean container. Save the fluid to refill the bath. 3. Raise the hood.
19. Calibrate the new viscometer tube. Replace Power Supply The CAV 4.1 power supply is a switching regulated power supply designed to handle 90 – 240 V . To accommodate different locations, only the MAINS AC power cable needs to be changed.
Company to conform to the weight, specifications and standards stated on the package. Returning a Product to CANNON Before returning a CANNON product for repair or service, make every attempt to identify the problem. If, after careful checking, the problem remains unidentified or unsolved, telephone CANNON Instrument Company (or the local service agent) to consult with a product specialist.
Please contact CANNON before returning a product that could possibly contain hazardous material. Shipping Notification Products returned without CANNON’s prior authorization will not be accepted. The customer may be billed a testing fee if a product is returned to CANNON and found to be working properly. CANNON Instrument Company® | Warranty...
Page 79
CANNON INSTRUMENT COMPANY® 2139 High Tech Road | State College, PA 16803 | USA 800-676-6232 | 814-343-8000 | Fax: 814-353-8007 sales@cannoninstrument.com | www.cannoninstrument.com...