Summary of Contents for National Instruments SET-1415
Page 1
Note Before you begin, complete the soft ware and hardware installati on procedures applicable to your applicati on. Note The guidelines in this document are specific to the SET-1415. The other components in the system might not meet the same safety rati ngs. Refer to the documentati on of each com- ponent in the system to determine the safety and EMC rati ngs for the enti re system.
Safety Guidelines Cauti on Do not operate the SET-1415 in a manner not specified in this document. Product misuse can result in a hazard. You can compromise the safety protecti on built into the product if the product is damaged in any way. If the product is damaged, return it for repair.
Page 3
Descripti on The carrier card of the SET-1415 Modular Input Card off er slots for eight functi on / measuring mo- dules of the SET “SMARTbrick” or “AEROspice” series. The SET-1415 serving diff erent applicati ons like simple signal routi ng and conditi oning up to complex signal simulati on via the “SMARTbrick” or “AEROspice”...
Page 4
Note You can configure the power-on configurati on in the soft ware. The factory default pow- er-on configurati on sets the front I/O channels to sinking input and rear I/O channels to input. 4 of 11 www.smart-e-tech.com SET-1415 Technical Descripti on Issue 01 12/06/2017...
Page 5
P1.0+ P1.0- REF_1+ P0.2+ REF_1- P0.2- P0.3+ P0.1+ P0.1- P0.3- P0.0+ P0.0- Signal Descripti on Px.y Line y in Port x No connecti on Reference J1 Connector Pin Assignments 5 of 11 www.smart-e-tech.com SET-1415 Technical Descripti on Issue 01 12/06/2017...
Page 6
XJ2 Connector Pinout (Rear) e d c b a 6 of 11 www.smart-e-tech.com SET-1415 Technical Descripti on Issue 01 12/06/2017...
Page 7
P3.2- P3.3+ P3.3- P4.0+ P4.0- P4.1+ P4.1- P4.2+ P4.2- P4.3+ P4.3- XJ2 Connector Pin Assignments Signal Descripti on Ground connecti on No connecti on XJ2 Connector Signal Descripti ons 7 of 11 www.smart-e-tech.com SET-1415 Technical Descripti on Issue 01 12/06/2017...
- Check the external power supply if used Blinking Red - Check fuse on board - Switch off and switch on the power supply (power cycle) - Please contact the support 9 of 11 www.smart-e-tech.com SET-1415 Technical Descripti on Issue 01 12/06/2017...
Modules 1-4 200mA Max. Current +15V Modules 5-8 200mA Modules 1-4 200mA Max. Current -15V Modules 5-8 200mA Max. Current Ref_x 1500mA by temp. rise from 30°C to Instrument X 10 of 11 www.smart-e-tech.com SET-1415 Technical Descripti on Issue 01 12/06/2017...
Page 11
Comment Operati ng Humidity Relati ve, 10%-90% non-condensing Storage Humidity Relati ve, 5%-95% non-condensing Operati ng Temperature Forced-air cooling from 0°C-40°C chassis Storage Temperature -40°C-85°C Maximum Alti tude 2000m 11 of 11 www.smart-e-tech.com SET-1415 Technical Descripti on Issue 01 12/06/2017...
Need help?
Do you have a question about the SET-1415 and is the answer not in the manual?