The installation template is on the back of the box.
Open up the box completely and rest it against the
wall.
Follow the installation sequence shown on the
folding leaf of the cover (Scheme 1), respecting
the minimum distance between the bottom of the
During installation, make sure the power cable is
disconnected from the power line.

3.2 ELECTRICAL CONNECTIONS

WARNING
To be installed by a specialised engineer in accord-
ance with the applicable standards in the country
concerned.
When the appliance is installed, make sure the pow-
er is off and the mains switch is in the "O" position.
The appliance requires a 230 V ~ 50 Hz power supply.
Make sure the power line is appropriate for the data
given in table 1.
Fig. 7
Appliance cable
If the Pilot Wire is not connected to the programming unit, it must be terminated and insulated. Under no
circumstances should the Pilot Wire be connected to the earth.
Make sure the power cable cannot in any way come into contact with the surface of the appliance (Fig. 6).
PHASE = BROWN
NEUTRAL = GREY
PILOT WIRE = BLACK
Two possible cases
Case 1: installation
without Pilot Wire
Case 2: installation with
Pilot Wire
disconnecting switch allowing the appliance to
be disconnected completely from the household
mains, included the Pilot Wire, when present, in
accordance with the wiring rules.
If the appliance is installed in a bathroom, the
sensitivity residual current protection device).
The power supply line and Pilot Wire control unit
must be protected by the same RCD.
Permanently connected appliances must be con-
nected using a connector block placed within a
proper junction box.
When installing the appliance in damp rooms
(kitchen, bathroom), the point of connection with
the household mains must be at least 25 cm from
lously.
PHASE
NEUTRAL
Terminate and insulate the wire
Connect to the Pilot Wire control
unit or transmission box
15
Household mains
GB
-